The proliferation of grid-forming (GFM) inverters in modern distribution networks has fundamentally altered the islanding-detection problem. Unlike grid-following converters, droop- and virtual-synchronous-generator (VSG)-controlled GFM units actively regulate voltage and frequency, suppressing the very deviations that conventional passive schemes rely upon and thereby enlarging the non-detection zone (NDZ) under near-balanced power conditions. This paper proposes a Physics-Informed Lightning-Search-Optimised Temporal Attention Network (PI-LSO-TAN) that jointly detects unintentional islanding and discriminates it from power-quality disturbances (PQDs) and non-islanding faults in GFM-dominated feeders. The framework fuses a physics-informed feature set rate-of-change-of-frequency (ROCOF) estimated from the analytic signal, total harmonic distortion, phase-jump and current-imbalance descriptors with a raw-window convolutional embedding processed by a self-attention pooling layer. A Lightning Search Algorithm (LSA) simultaneously optimises the network hyperparameters and a physics-informed decision threshold, removing manual tuning. Across 10 independent dataset realisations of a documented, fully reproducible synthetic GFM feeder operated in the near-balanced NDZ regime, PI-LSO-TAN attains a four-class test accuracy of 96.34% (SD 0.96 percentage points), a macro-F1 of 0.9636 and an islanding recall of 93.49% at an islanding false-positive rate of 0.70%, misdeclaring 2.40 of 175 power-quality windows as islanding. Two findings define what the method does and does not contribute. First, when ten baselines spanning kernel, ensemble, convolutional, recurrent, attention-based and graph architectures are given the identical physics-informed side-channel, all 11 models fall within 1.20 percentage points of one another; none of the 6 deep sequence architectures differs significantly from the proposed model under Holm-corrected Wilcoxon tests, and of the ten baselines only 1 differ significantly at all MLP-SVM hybrid, ahead by up to 0.73 percentage points these being among the simplest feature-space classifiers in the comparison. On this task the discriminative power resides in the physics-informed representation rather than in the temporal-modelling mechanism. Substituting an alternative fourteen-dimensional representation confirms this directly principal components of the raw window reach 52.37%, wavelet band energies 73.60%, generic statistics 62.94%, and a purely learned embedding 30.17%, against 96.20% for the physics-informed set. Second, noise resilience is a property of the training distribution, not of the architecture: training at a single SNR leaves accuracy at 52.18% when the measurement noise floor moves to 30dB, whereas sampling the training SNR across 15 dB to 50 dB restores 88.79% at 30dB and 84.54% at 20dB for a cost of − 6.14 percentage points at the nominal operating point. The practical contribution is protective rather than architectural. A security-calibrated passive over/under-frequency, ROCOF and over/under-voltage relay detects none of the 3872 scanned near-balanced islanding events, leaving a 100.0% non-detection area, whereas the proposed detector reduces it to 0.00%, with no cell of the power-mismatch plane falling below 87.5% detection. Measured sliding-window detection latency is 80 ms on average and 130 ms at the 95th percentile, inside the 2 s envelope of IEEE 1547-2018 and IEC 62116, at 337 μsof computation per window and 28.7 kB of parameters. The results indicate that reliable anti-islanding protection in inverter-dominated grids is obtained by pairing a physics-informed representation with noise-augmented training, and that the resulting detector covers a region of the operating plane in which conventional passive protection is blind by construction.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: