Key result
Stepwise 5-mm lattice-tip catheter repositioning pinpoints discrete non-PV atrial fibrillation triggers.
Why the study?
Does detailed step-by-step mapping with a lattice-tip catheter improve the identification of non-PV triggers in patients with paroxysmal atrial fibrillation?
Case Report (n=1)
No
Does detailed step-by-step mapping with a lattice-tip catheter improve the identification of non-PV triggers in patients with paroxysmal atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Careful step-by-step mapping with a lattice-tip catheter can identify small, discrete local electrograms to accurately pinpoint non-PV triggers for atrial fibrillation ablation.
At the origin of the non-PV trigger, a small discrete pre-potential-like electrogram was recorded using a lattice-tip catheter after 5-mm catheter repositioning, preceding the potential at the previous site by 56 ms.
No takes yet. Share an insight, caveat, or question.
Matsunaga‐Lee et al. (2026) conducted a case report in Paroxysmal atrial fibrillation (AF) (n=1). Lattice-tip catheter (Sphere-9) step-by-step mapping and pulsed field ablation was evaluated on Identification of discrete pre-potential-like electrogram and freedom from palpitations. Step-by-step 5-mm repositioning of a lattice-tip catheter successfully identified a discrete pre-potential-like electrogram at the origin of a non-PV atrial fibrillation trigger.
Synapse has enriched 10 related papers. Consider them for comparative context: