Why the study?
Comparative real-world data on newer balloon-expandable valve platforms for TAVR remain limited, necessitating evaluation of clinical, procedural, and hemodynamic outcomes.
Does transcatheter aortic valve replacement with the MyVal platform compared to the Sapien platform improve or affect 2-year survival and procedural safety in patients with severe aortic stenosis?
Observational (n=1,903)
Yes
Does transcatheter aortic valve replacement with the MyVal platform compared to the Sapien platform improve or affect 2-year survival and procedural safety in patients with severe aortic stenosis?
Absolute Event Rate: 15% vs 19%
p-value: p=0.6
While contemporary balloon-expandable valves demonstrate comparable 2-year survival, the MyVal platform is associated with higher rates of permanent pacemaker implantation and moderate-or-greater paravalvular leak compared to the benchmark Sapien platform.
Background Comparative real-world data on newer balloon-expandable valve (BEV) platforms remain limited. We sought to compare clinical, procedural, and early hemodynamic outcomes following transcatheter aortic valve replacement (TAVR) using 2 contemporary balloon-expandable valves in a multicenter international registry. Methods Consecutive patients undergoing TAVR with Sapien 3/Ultra and MyVal from the AMTRAC multicenter registry were included. Propensity score matching (PSM) was used to generate a balanced 1:3 cohort. The primary endpoint was 2-year all-cause mortality. Secondary endpoints included in-hospital complications, defined according to Valve Academic Research Consortium–3 criteria. Results A total of 1903 patients undergoing TAVR with BEV were included (Sapien, n=1676; MyVal, n=227). Baseline clinical and echocardiographic characteristics were largely comparable between groups. In the propensity-matched cohort (n = 743), 2-year all-cause mortality did not differ between groups. In-hospital mortality and major procedural complications were similar across platforms. New permanent pacemaker implantation (PPI) occurred more frequently with MyVal compared with Sapien (26.6% vs.10.1%; p < 0.001). Postprocedural mean transvalvular gradients were comparable between valves, but a greater proportion of Sapien recipients had elevated mean gradients (>10mmHg), (44.0% vs.32.3%; p=0.019). Paravalvular leak (PVL) distribution differed, with more-than-mild PVL observed more frequently in the MyVal group (9.8% vs.2.1%; p < 0.001). Conclusions In this analysis, both BEV platforms demonstrated comparable safety, mortality, and overall hemodynamic performance following TAVR. However, MyVal was associated with higher rates of PPI and PVL. These findings highlight important platform-specific differences that may inform valve selection and warrant further long-term evaluation.
No takes yet. Share an insight, caveat, or question.
Talmor‐Barkan et al. (2026) conducted an observational in Severe, symptomatic aortic stenosis (n=1,903). MyVal transcatheter heart valve vs. Edwards Sapien transcatheter heart valve (Sapien 3 / Ultra) was evaluated on All-cause 2-year mortality (p=0.6).