Key result
Cement-augmented pedicle screw instrumentation causes fatal intracardiac cement embolism and cardiac tamponade.
Why the study?
Cement-augmented pedicle screw instrumentation can cause rare but fatal intracardiac cement embolism, a complication requiring increased clinical awareness.
Case Report (n=1)
No
Intracardiac cement embolism is a rare but catastrophic complication of cement-augmented spinal instrumentation that requires prompt multimodal imaging and early recognition to manage structural cardiac injuries and tamponade.
Alerts clinicians to fatal tamponade risk from cement embolism in spinal instrumentation; leaves optimal prevention strategies open.
Background: Cement-augmented pedicle screw instrumentation (CAPSI) is a widely used surgical technique for spinal stabilization and decompression, particularly in patients with poor bone quality. Although generally considered safe, cement extravasation can result in severe complications, including neurological injury and embolic events involving pulmonary or cardiac structures. Intracardiac cement embolism is a rare but potentially fatal occurrence. Case Presentation: A 67-year-old man with a history of hypertension and advanced renal cancer under palliative care presented with a 1-week history of severe lumbar pain radiating to the right lower limb, accompanied by progressive weakness in both legs. Magnetic resonance imaging revealed an infiltrative soft tissue mass extending from T12 to L2 with spinal canal compression and metastatic-appearing sacroiliac bone lesions. The patient underwent open posterior decompression with CAPSI using polymethylmethacrylate. Within 24 h postoperatively, he developed acute dyspnea and oppressive retrosternal chest pain. A contrast-enhanced chest CT revealed hyperdense material consistent with cement within the inferior vena cava, pulmonary arteries, and right ventricle, with perforation of the posterior ventricular wall and extravasation into the anterior esophageal wall. Transesophageal echocardiography confirmed a 53-mm linear, hyperechoic structure spanning the right atrium and perforating the anterior leaflet of the tricuspid valve, resulting in significant tricuspid regurgitation. A second cement fragment, located outside the atrial cavity, was associated with a mild pericardial effusion. Surgical intervention was recommended but declined by the patient. He subsequently developed obstructive shock due to cardiac tamponade and died. Discussion: This case highlights a rare but catastrophic complication of CAPSI. Accidental cement migration into the venous system can lead to cardiac perforation, even after an apparently uneventful surgical procedure. Prompt clinical suspicion and multimodal imaging are critical to identifying and managing this potentially fatal condition.
No takes yet. Share an insight, caveat, or question.
Reyes et al. (2026) conducted a case report in Metastatic spinal cord compression (n=1). Cement-augmented pedicle screw instrumentation (CAPSI) was evaluated. Cement-augmented pedicle screw instrumentation resulted in a fatal intracardiac cement embolism causing right ventricular perforation and cardiac tamponade within 24 hours postoperatively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: