Key result
Preoperative IABP is linked to ~18% lower odds of MACCE after mitral regurgitation surgery.
Why the study?
Evidence supporting preoperative intra-aortic balloon pump use in patients undergoing surgical mitral regurgitation correction remains scarce.
Does preoperative intra-aortic balloon pump use improve clinical outcomes in patients undergoing surgery for mitral regurgitation?
Cohort (n=33,644)
Yes
Does preoperative intra-aortic balloon pump use improve clinical outcomes in patients undergoing surgery for mitral regurgitation?
Odds Ratio: 0.82 (95% CI 0.68–0.98)
Absolute Event Rate: 16.8% vs 19.6%
p-value: p=0.041
Preoperative IABP use is associated with reduced in-hospital major adverse cardiac and cerebrovascular events (MACCE) and mortality in patients undergoing surgical correction for mitral regurgitation, with the greatest benefit seen in patients with severe baseline illness.
Should not yet change practice; leaves open need for RCTs to confirm benefit in high-acuity mitral surgery.
BACKGROUND: Mitral regurgitation (MR) requiring surgical correction poses significant perioperative challenges, particularly in hemodynamically compromised patients. Evidence supporting preoperative intra-aortic balloon pump (IABP) use in this setting remains scarce. This study evaluated the association between preoperative IABP use and clinical outcomes in patients undergoing surgical MR correction. METHODS: We conducted a retrospective cohort study utilizing the Nationwide Readmissions Database (NRD) from 2016 through 2020. Adult patients undergoing surgical mitral valve repair or replacement were identified using validated ICD-10-CM and ICD-10-PCS codes. Patients who received preoperative IABP were compared with those who did not through 1:1 propensity score matching, accounting for baseline clinical characteristics and illness severity. The primary outcome was major adverse cardiac and cerebrovascular events (MACCE). Secondary outcomes included in-hospital mortality, perioperative complications, 30-day readmissions, and length of stay. RESULTS: Among 33,644 hospitalizations for surgical MR correction, 1,691 (5.0%) involved preoperative IABP use. Following propensity score matching, 964 pairs were analyzed. Preoperative IABP use was associated with significantly lower rates of MACCE (16.8% vs. 19.6%, P = 0.045), in-hospital mortality (4.7% vs. 6.5%, P = 0.028), ischemic stroke (1.5% vs. 2.3%, P = 0.040), and prolonged mechanical ventilation (7.9% vs. 10.2%, P = 0.014). Thirty-day readmission rates and length of stay were also lower among IABP recipients. CONCLUSIONS: Preoperative IABP use was associated with modestly improved in-hospital outcomes and lower short-term readmissions, with the most pronounced benefits among high-acuity patients. These hypothesis-generating findings support a selective, severity-guided role for preoperative IABP, warranting prospective validation.
No takes yet. Share an insight, caveat, or question.
Bahar et al. (2026) conducted a cohort in Mitral regurgitation (n=33,644). Preoperative intra-aortic balloon pump vs. No preoperative intra-aortic balloon pump was evaluated on Major adverse cardiac and cerebrovascular events (MACCE) (aOR 0.82, 95% CI 0.68-0.98, p=0.041). Preoperative intra-aortic balloon pump exposure was associated with significantly lower odds of MACCE (aOR 0.82) compared to no IABP in patients undergoing surgical correction for mitral regurgitation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: