Key result
Proximal left bundle targeting linked to ~4.1-fold higher odds of near-native activation vs distal targeting.
Its licence doesn't allow us to show a copy here.
Why the study?
Implantation electrical criteria for left bundle branch capture in conduction system pacing cannot localize the lead along the conduction axis, limiting understanding of optimal lead positioning.
Does proximal lead positioning in conduction system pacing improve near-native paced activation compared to distal positioning in patients undergoing CSP?
Observational (n=186)
Does proximal lead positioning in conduction system pacing improve near-native paced activation compared to distal positioning in patients undergoing CSP?
Odds Ratio: 4.14 (95% CI 1.23–13.96)
Absolute Event Rate: 62% vs 27%
p-value: p=0.021
Quantitative computed tomography reveals that proximal left bundle targeting during conduction system pacing results in superior physiologic pacing compared to distal positioning, which cannot be identified by surface ECG or procedural label alone.
BACKGROUND: Implantation electrical criteria for left bundle branch capture in conduction system pacing (CSP) cannot localize the lead along the conduction axis. OBJECTIVES: The goals of this study were to classify CSP lead position with an observer-independent computed tomography workflow (CARA workflow) using 2 anatomic measurements-lead-to-His distance (LH) and lead-to-endocardium offset (LE)-and to test whether a proximal position yields near-native paced activation. METHODS: Of 186 consecutive patients undergoing CSP, 145 had interpretable computed tomography anatomy. Leads were classified by a prespecified rule: left ventricular septal pacing if LE ≤ -2.5 mm; otherwise, proximal (LH ≤ 25 mm) or distal (LH > 25 mm), with 25 mm referenced to left bundle histology. The primary analysis set included patients in sinus rhythm, native QRS duration < 115 ms, complete paired electrocardiograms (ECGs), and LE > -2.5 mm (n = 46). The primary end point was |Δ frontal axis| ≤ 15° and |Δ QRS duration| ≤ 15 ms. RESULTS: Classification yielded 68 proximal, 70 distal, and 7 left ventricular septal pacing leads. The procedural label carried no positional information (48% of physician-labeled left bundle branch pacing leads were proximal vs 49% overall). The composite end point occurred in 15 of 24 proximal leads (62%) vs 6 of 22 distal leads (27%) (odds ratio 4.14; 95% confidence interval 1.23-13.96; P = .021; adjusted odds ratio 5.35; P = .013), a finding consistent across sensitivity analyses. The receiver operating characteristic-optimal LH cut point (24.9 mm) independently reproduced the prespecified 25-mm threshold. Position was not recoverable from the surface ECG (classification area under the curve 0.48). CONCLUSION: In this proof-of-concept anatomic study, a 2-measurement rule classified CSP lead position objectively. Near-native paced activation requires proximal targeting (LH ≤ 25 mm), which neither the procedural label nor the ECG can identify; quantitative imaging is required.
No takes yet. Share an insight, caveat, or question.
Ponnusamy et al. (2026) conducted an observational in Conduction system pacing (n=186). Proximal left bundle targeting (lead-to-His distance ≤ 25 mm) vs. Distal left bundle targeting (lead-to-His distance > 25 mm) was evaluated on |Δ frontal axis| ≤ 15° and |Δ QRS duration| ≤ 15 ms (OR 4.14, 95% CI 1.23-13.96, p=0.021). Proximal left bundle targeting yielded significantly more near-native paced activation than distal targeting (62% vs 27%; OR 4.14; 95% CI 1.23-13.96; P=0.021).