Why the study?
A slow, regular ventricular response during typical atrial flutter can conceal complete atrioventricular block, complicating diagnosis in decompensated heart failure patients.
Case Report (n=1)
A slow, regular ventricular response in typical atrial flutter may mask concealed complete AV block, which can be successfully managed with ablation and left bundle branch area pacing-optimized CRT to improve heart failure symptoms.
A slow, regular ventricular response during typical atrial flutter, especially with alternating bundle branch block, should raise suspicion of concealed complete atrioventricular block. We report a 73-year-old man with decompensated heart failure (ejection fraction 25%) in whom typical flutter masked advanced infra-Hisian block. Cavotricuspid isthmus ablation terminated the flutter and unmasked complete atrioventricular block (QRS 160 ms). Left bundle branch area pacing-optimized cardiac resynchronization therapy with intentional anodal capture narrowed the QRS to 90 ms, with early clinical improvement.
No takes yet. Share an insight, caveat, or question.
Vo et al. (2026) conducted a case report in Decompensated heart failure and typical atrial flutter with concealed complete atrioventricular block (n=1). Cavotricuspid isthmus ablation and left bundle branch area pacing-optimized cardiac resynchronization therapy was evaluated.