Key result
Wider preprocedural CT Vectorial Angle linked to ~6% lower odds of post-TAVI pacemaker per degree.
Why the study?
Conduction disturbances requiring permanent pacemaker implantation remain a frequent complication after balloon-expandable TAVI, and novel predictors are needed to improve risk stratification.
Does the preprocedural CT-derived Vectorial Angle predict the requirement for permanent pacemaker implantation in patients with severe symptomatic aortic stenosis undergoing balloon-expandable TAVI?
Cohort (n=67)
Does the preprocedural CT-derived Vectorial Angle predict the requirement for permanent pacemaker implantation in patients with severe symptomatic aortic stenosis undergoing balloon-expandable TAVI?
The CT-derived Vectorial Angle is a novel, independent predictor of permanent pacemaker requirement after balloon-expandable TAVI, highlighting the importance of the valve's maximal radial force orientation relative to conduction tissue.
Conduction disturbances requiring permanent pacemaker (PPM) implantation remain a frequent complication of transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the "Vectorial Angle"-a novel computed tomography (CT)-derived biomechanical parameter-alongside traditional anatomical and electrocardiographic predictors of PPM following balloon-expandable TAVI. This retrospective cohort study included 67 patients with severe symptomatic aortic stenosis undergoing TAVI with the balloon-expandable Myval system. The Vectorial Angle was defined on preprocedural CT at the elliptical left ventricular outflow tract (e-LVOT) level as the angular deviation between the minor axis (representing the axis of maximal radial expansion force) and the midpoint of the right coronary to noncoronary (RCCNCC) commissure (approximating the anatomical course of the conduction system).PPM implantation was required in 12 patients (17.9%). In multivariate logistic regression analysis, a narrower Vectorial Angle (OR 0.935 per 1° increment, 95% CI 0.889 to 0.982; p = 0.007) and a shorter membranous septal length (MSL) (OR 0.447 per 1 mm increment, 95% CI 0.241 to 0.831; p = 0.011) emerged as the only independent predictors of PPM requirement. Valve oversizing index was not associated with PPM implantation (p = 0.954). Implantation depth was numerically greater in the PPM group but did not reach independent predictor status (p = 0.079). Pre-existing right bundle branch block (RBBB) lost independent predictive value after adjustment for these structural parameters. Receiver operating characteristic (ROC) curve analysis for the Vectorial Angle yielded an area under the curve of 0.806 (p = 0.001), with an optimal cutoff of ≤52°. The Vectorial Angle is a novel, independent preprocedural predictor of PPM after balloon-expandable TAVI. This finding highlight that the spatial orientation of the valve's maximal radial force relative to the conduction tissue is a potential anatomical determinant associated with conduction-system vulnerability, complementing conventional anatomical assessments such as MSL.
No takes yet. Share an insight, caveat, or question.
Doğan et al. (2026) conducted a cohort in Severe symptomatic aortic stenosis (n=67). Vectorial Angle was evaluated on Permanent pacemaker (PPM) implantation (OR 0.935 per 1° increment, 95% CI 0.889 to 0.982, p=0.007). A narrower Vectorial Angle on preprocedural CT was an independent predictor of permanent pacemaker requirement following balloon-expandable TAVI (OR 0.935 per 1° increment; 95% CI 0.889-0.982; p=0.007).