Answers are grounded in this paper and cite their sources.
We aimed to assess whether deep inspiration breath-hold (DIBH) could reduce esophageal dose by spinal stereotactic body radiotherapy (SBRT). In 25 patients with thoracic DIBH CT, the vertebral–esophageal distance significantly increased at T2–T9, greatest at Th7 (median 2.1 mm). Simulated SBRT plans showed a strong correlation between distance and esophageal dose, each 1 mm increase reducing 150 cGy. DIBH reduced the esophageal D 0.03 cc dose by a median of 411 cGy while maintaining positional reproducibility within 2 mm. These findings suggest that DIBH may reduce esophageal dose and warrants further study in patients with prior high-dose esophageal exposure.
No takes yet. Share an insight, caveat, or question.
Aoyama et al. (2025) studied this question.