Answers are grounded in this paper and cite their sources.
This paper investigates the effects of electrical conductivity models of a lossy dielectric on current pulses and surface charge accumulation in a needle-plane electrode system. Two constant-conductivity cases were compared with a nonlinear model dependent on electric field and temperature. For the nonlinear model, uniform 30°C and temperature-gradient conditions were considered separately. The constant-conductivity cases showed similar pulse magnitudes but different timings, while the temperature-fixed nonlinear model caused only limited changes. In contrast, the temperature-gradient model produced clear differences in current pulses and surface charge distribution. At the same interface position, the surface charge density decreased by about 90%, and the location of maximum charge accumulation shifted. These results show that spatial variations in conductivity due to electric field and temperature significantly affect transient discharge and interfacial charge behavior.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: