Key result
Higher implanter volume linked to ~7% lower odds of leadless pacemaker perforation per 10 implants.
Why the study?
Device complications after leadless pacemaker implantation and their association with patient, implanter volume, and facility characteristics over time were not well characterized.
Does higher implanter volume and increased temporal experience reduce cardiac perforation rates in patients receiving tined leadless pacemakers?
Observational (n=46,698)
Yes
Does higher implanter volume and increased temporal experience reduce cardiac perforation rates in patients receiving tined leadless pacemakers?
Cardiac perforation rates during tined leadless pacemaker implantation have significantly decreased over time, and safety is strongly correlated with higher implanter volume.
May warrant volume-based referral for leadless pacemakers; leaves open causal effects in prospective studies.
BACKGROUND: As leadless pacing approaches a decade in clinical practice, we sought to assess how device complications have changed over time, and how variations in patient, implanter volume, and facility characteristics are associated with these changes. OBJECTIVE: To examine rates of cardiac perforations after leadless pacemaker implantation over time, and the associations between patient, implanter volume, and facility characteristics with these outcomes, including the extent of variation attributable to implanters and facilities. METHODS: Medicare claims linked to a manufacturer's device registration data were used to identify patients implanted with a tined leadless pacemaker from 2017 to 2024. Patient selection across implanters and facilities was evaluated by examining differences in patient characteristics and their impact on patient-adjusted model estimates. Random-intercept models were fitted to estimate variation attributable to implanters and facilities. RESULTS: Among 46,698 implants, 19,446 (41.6%) were Micra AV; patients had a mean age of 80.4 years and a high Charlson Comorbidity Index (4.7±3.4). Cardiac perforation rates declined over time (adjusted Coefficient -0.13, 95% CI -0.19 - -0.06, p-value<0.01). Higher implanter volume was associated with fewer perforations (OR 0.93 per additional 10 implants, 95% CI 0.88-0.98; p-value<0.01). Differences in patient characteristics across providers and facilities were observed; however, adjustment for these differences did not materially alter the associations between implanters and facility and perforation rates. CONCLUSION: In Medicare patients with tined leadless pacemakers, cardiac perforation rates declined over time and were lower in those implanted by more experienced implanters. Variation in outcomes was more closely associated with implanters than facilities.
No takes yet. Share an insight, caveat, or question.
Piccini et al. (2026) conducted an observational in Pacemaker indication (n=46,698). Higher implanter volume vs. Lower implanter volume was evaluated on Cardiac perforations (OR 0.93, 95% CI 0.88-0.98, p=<0.01). Higher implanter volume of tined leadless pacemakers was associated with fewer cardiac perforations (OR 0.93 per additional 10 implants; 95% CI 0.88-0.98; P<0.01).