Key result
Low LAAeV below 40.5 cm/s linked to ~8.2-fold higher post-ablation AF recurrence at 1 year.
Why the study?
AF recurrence after radiofrequency catheter ablation remains challenging, and the value of left atrial appendage function measured by TEE to predict recurrence in paroxysmal AF patients is unclear.
Cohort (n=81)
No
Hazard Ratio: 8.194 (95% CI 2.98–22.53)
p-value: p=<0.001
May aid post-ablation AF recurrence risk stratification; hypothesis-generating and requires prospective validation.
Atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA) remains a challenging issue. This study aims to explore the left atrial appendage function by transesophageal echocardiography (TEE) and assess its value in predicting AF recurrence following RFCA in paroxysmal AF patients. Eighty-one patients with paroxysmal AF that underwent RFCA were recruited. TEE was performed before ablation with the assessment of left atrial appendage emptying flow velocity (LAAeV). AF recurrence occurred in 24 patients (29.6%) within 12 months after RFCA. The left atrium diameter (LAD) and left atrium volume index (LAVI) were both significantly higher in the recurrence group compared to the non-recurrence group, while the LAAeV was significantly lower in the recurrence group. LAD, LAVi and LAAeV were univariately significant risk factors for AF recurrence after ablation. Based on receiver operating curve (ROC), LAAeV < 40.5 cm/s, LAVi > 40.5 mL and LAD > 41 mm were identified as cut-off values for predicting AF recurrence. In multivariate regression analysis LAAeV < 40.5 cm/s (HR 8.194, 95% CI 2.980–22.530, p < 0.001) was identified as the only statistically significant independent predictor of AF recurrence, as the statistical significance threshold was not achieved for LAVI > 40.5 mL and LAD > 41 mm (p = 0.319; p = 0.507, respectively). A low LAAeV was the only important independent predictor of AF recurrence within 1 year after first RFCA.
No takes yet. Share an insight, caveat, or question.
Istrătoaie et al. (2021) conducted a cohort in Paroxysmal Atrial Fibrillation (n=81). Left atrial appendage emptying flow velocity (LAAeV) < 40.5 cm/s vs. LAAeV ≥ 40.5 cm/s was evaluated on Atrial fibrillation recurrence within 12 months after radiofrequency catheter ablation (HR 8.194, 95% CI 2.980-22.530, p=<0.001). A left atrial appendage emptying flow velocity (LAAeV) of less than 40.5 cm/s independently predicted a significantly higher risk of atrial fibrillation recurrence (HR 8.194) within 1 year after radiofrequency catheter ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: