This is the authors' abstract. We don't add key points for this paper.
This study aims to evaluate the effects of different finishing and polishing (F/P) systems on gloss and surface morphology of a new nanocomposite. Thirty discs of Filtek Universal Restorative material (3 M, ESPE) were prepared and divided into six groups (n = 5). Group A and B followed F/P protocols for anterior restorations, whereas Group C and D for posterior ones. Group E represented the control (covered by Mylar strip) and Group F represented the nanocomposite placement by means of clinical hand instruments; Groups E and F did not undergo F/P procedures. Among the polished groups, Group B showed the highest values (68.54 ± 7.54 GU), followed by Group A and D (46.87 ± 5.52 GU; 53.76 ± 2.65 GU). Finally, Group C (37.38 ± 4.93 GU) displayed the lowest results. Overall, Group E showed the highest gloss values (93.45 ± 8.27 GU), while Group F presented the lowest ones (1.74 ± 0.64 GU). Surface analysis revealed that Group A, C, and D displayed a smooth surface. Group B showed the lowest irregularities. Group E exhibited the most uniform superficial morphology. On the other hand, Group F displayed the most irregular one. In conclusion, using the tested material, only two protocols achieved appropriate gloss values. Then, clinicians might use the protocols of Group B and Group D, for anterior and posterior restorations, respectively.