Key result
FREE-DSA trial evaluates noninferiority of non-fluoroscopic catheter ablation safety versus traditional DSA lab.
Why the study?
Prospective randomized evidence evaluating the safety and efficacy of RFCA performed in a non-fluoroscopic catheterization laboratory is limited.
Does radiofrequency catheter ablation in a non-fluoroscopic laboratory demonstrate noninferior safety compared to a traditional DSA laboratory in patients with paroxysmal AF or SVT?
RCT (n=1,260)
Open-label
1:1
Yes
Does radiofrequency catheter ablation in a non-fluoroscopic laboratory demonstrate noninferior safety compared to a traditional DSA laboratory in patients with paroxysmal AF or SVT?
Answers are grounded in this paper and cite their sources.
The FREE-DSA trial will evaluate the noninferiority of radiofrequency catheter ablation performed in a non-fluoroscopic laboratory compared to traditional DSA laboratories for paroxysmal AF and SVT.
Background Conventional radiofrequency catheter ablation (RFCA) has historically relied on fluoroscopic guidance, exposing patients and operators to ionizing radiation and contributing to cumulative occupational hazards. Although intracardiac echocardiography and three-dimensional electroanatomical mapping have enabled non-fluoroscopic ablation, prospective randomized evidence evaluating RFCA performed in a non-fluoroscopic catheterization laboratory remains limited. Objective This study aimed to evaluate whether RFCA performed in a non-fluoroscopic catheterization laboratory is noninferior to RFCA performed in a traditional DSA catheterization laboratory regarding procedural safety and acute procedural efficacy in patients with paroxysmal atrial fibrillation (AF) or supraventricular tachycardia (SVT). Methods The FREE-DSA trial is an investigator-initiated, multicenter, open-label, randomized, parallel-group, noninferiority trial conducted in China. A total of 1,260 patients with symptomatic paroxysmal AF or paroxysmal SVT will be enrolled from at least 10 centers and randomized in a 1:1 ratio to undergo RFCA in either a non-fluoroscopic catheterization laboratory or a traditional DSA catheterization laboratory. Randomization is stratified by participating center and arrhythmia type. Clinical endpoints will be adjudicated by an independent committee blinded to treatment allocation. Results The primary safety endpoint is the incidence of procedure-related complications occurring during the index procedure or within 3 months after ablation. The key secondary procedural efficacy endpoint is immediate procedural success. Additional secondary endpoints include procedural times, radiation exposure, hospitalization-related economic outcomes, and 3-month arrhythmia recurrence. Conclusion The FREE-DSA trial will provide randomized evidence regarding the safety and feasibility of RFCA in a non-fluoroscopic catheterization laboratory and may inform future radiation-sparing electrophysiology practice.
No takes yet. Share an insight, caveat, or question.
Du et al. (2026) conducted an RCT in Paroxysmal atrial fibrillation or supraventricular tachycardia (n=1,260). Radiofrequency catheter ablation in a non-fluoroscopic catheterization laboratory vs. Radiofrequency catheter ablation in a traditional DSA catheterization laboratory was evaluated on Incidence of procedure-related complications occurring during the index procedure or within 3 months after ablation. The FREE-DSA trial will randomize 1,260 patients to evaluate if radiofrequency catheter ablation in a non-fluoroscopic lab is noninferior to a traditional DSA lab regarding procedural safety.