Answers are grounded in this paper and cite their sources.
Physical clogging limits managed aquifer recharge (MAR), yet the threshold-crossing time alone may not predict subsequent performance. Constant-head columns packed with borosilicate glass beads or quartz sand received a 50 mg L−1 silica suspension (0.9–2.7 μm) for 240 h. Hydraulic heads and discharge yielded relative apparent hydraulic-conductivity trajectories (Kr); X-ray computed tomography supported box-counting and block-network analyses. Sustained crossings below Kr=0.60, 0.50, and 0.40 occurred at 44/46, 61/59, and 88/78 h for the glass-bead/quartz-sand columns. Despite similar 0.60 and 0.50 crossing times, Kr values at 240 h were 0.475 and 0.043, respectively. The glass-bead trajectory rebounded after its minimum and remained above 0.40. Interface box-counting slopes depended on imaging branch and segmentation threshold, but the regional D2 and D3 ranks remained positively associated within each medium. Removing the highest-flow 5% of flow-carrying edges caused conductance-proxy losses of 0.521–0.692 across three capacity laws, greater than under random removal. For the two tested cases, threshold persistence, subsequent direction, and terminal state provided complementary evidence of hydraulic stability; broader application requires replicated tests across particle and loading conditions while retaining the distinction between obstruction probability and flow-path consequence.
No takes yet. Share an insight, caveat, or question.
A 2026 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: