Answers are grounded in this paper and cite their sources.
Low-alkalinity geopolymer coral aggregate concrete (GPCAC), incorporating seawater, sea sand, waste coral aggregates, and a durable geopolymer binder, offers significant advantages in terms of in-situ utilization of marine resources, reduced carbon emissions, and excellent durability. Combined with corrosion-resistant basalt fiber-reinforced polymer (BFRP) bars, GPCAC exhibits considerable potential for marine engineering applications. However, the interfacial bond behavior between BFRP bars and GPCAC plays a critical role in ensuring effective load transfer, reliable anchorage, and structural performance of structural members under repeated loading. Despite its importance, the bond degradation mechanisms and constitutive relationships between BFRP bars and GPCAC under cyclic loading remain unclear. In this study, central pull-out tests under cyclic loading were conducted to systematically investigate the effects of initial cyclic displacement and bond length on the interfacial bond performance between BFRP bars and GPCAC, with cement-based coral aggregate concrete (CAC) as a reference. The results demonstrated that both GPCAC and CAC specimens exhibited pronounced hysteretic characteristics and cumulative damage under cyclic loading. Increasing the initial cyclic displacement or bond length resulted in continuous reductions in bond strength and bond stiffness. Compared with specimens under monotonic loading, the bond strength of GPCAC specimens decreased by approximately 9.5%, 16.0%, and 19.1% at initial cyclic displacements of 0.1 mm, 0.2 mm, and 0.3 mm, respectively. Correspondingly, the bond stiffness at a slip of 0.40 mm weakened by approximately 20.3%, 38.3%, and 43.9%, respectively. These reductions were mainly attributed to repeated interfacial crack initiation and closure, as well as the progressive deterioration of mechanical interlocking and friction due to wear of BFRP bar ribs. Notably, GPCAC specimens exhibited superior bond performance to CAC specimens under cyclic loading, with improvements of 9.7%-15.6% in bond strength and 3.4%-17.8% in bond stiffness. Furthermore, a cyclic bond stress-slip constitutive model for the BFRP bar-GPCAC interface was developed and verified, showing good agreement with experimental results. The findings provide valuable insights into the bond behavior and structural performance assessment of BFRP bar-reinforced GPCAC structures subjected to repeated and reversed cyclic loading.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: