Answers are grounded in this paper and cite their sources.
Cell-to-cell inconsistency limits the usable capacity and service life of series-connected lithium-ion battery packs. This simulation study evaluates active balancing of a four-cell pack in which a shared Cuk converter, connected through a dual-layer donor/receiver switch matrix, is driven by a cascaded controller. A Mamdani fuzzy inference system converts the average pack state of charge (SOC) and the SOC spread into an equalization-current reference (0–5 A), and a continuous-time PID block, tuned to integral-only action, tracks this reference through 10 kHz PWM with the duty ratio limited to 0.75. Each cell is a second-order RC model with SOC-dependent parameters adopted from a published identification study; all cells share these parameters, and imbalance is imposed through initial SOC values of 55%, 50%, 45% and 47%. With fuzzy-PID control the cells converged in about 415 s at rest, 390 s during discharge and 350 s during charge, compared with 575, 800 and 700 s for conventional fuzzy control (27.8–51.3% shorter). The model-level donor-to-receiver energy-transfer index was 87.52%. Because the cells are identical, SOC feedback is ideal and no hardware was tested, the results are a simulation proof of concept; sensitivity bounds and the validation required before EV use are reported.
No takes yet. Share an insight, caveat, or question.
Lammecha et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: