Hybrid installations that combine a solar inverter and battery with the utility grid are increasingly common in Uganda, yet they are typically managed by threshold-based automatic transfer switches (ATS) that ignore solar availability, grid quality, and load criticality. This paper presents the design, modelling, and simulation-based evaluation of a multi-input fuzzy logic based hybrid load balancing controller. The framework fuses four inputs (solar output, battery state of charge (SOC), grid status, and load demand) through a Mamdani-type fuzzy inference system to produce two coordinated outputs: a source-priority signal and a tiered load-shedding signal spanning three load classes (critical, flexible, and non-essential). The study is entirely simulation-based. The system was implemented in Python at one-minute resolution over a synthetic but representative 24-hour scenario featuring two grid outages, a brownout, and cloud-induced solar variability, and was benchmarked against a conventional threshold-based transfer switch, an ATS with critical-load priority, and a crisp rule-based tiered controller; it was further tested on seven stress cases and a 100-run Monte Carlo evaluation. In the headline scenario the fuzzy controller sustained 100% availability of critical load against 91.9% for the baseline, which suffered 67 minutes of complete blackout; raised solar utilisation from 47.1% to 100%; cut grid energy from 13.43 kWh to 7.95 kWh (40.8%); and reduced source-switching events from four to two. These gains came from deliberately curtailing all non-essential load and 4.6% of flexible load, so they are not a pure efficiency gain: total unserved energy rose from 1.84 to 3.18 kWh, although a criticality-weighted reliability index still favoured the fuzzy controller (96.4% versus 92.6%). Broader testing confirmed the solar-utilisation and grid-energy advantages over the threshold baseline, but showed that an ATS with simple critical-load priority protected critical load at least as well under stress, identifying rule-base tuning as the main need. The results support a simulation-based proof of concept. A real-time embedded demonstration, in which the controller and plant model ran on a Raspberry Pi 5 with an external touch display using emulated inputs, reproduced the simulated behaviour; testing with live sensors and relays and field validation remain future work.
No takes yet. Share an insight, caveat, or question.
Wanzala et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: