Approximate multiplication suits image filters when the arithmetic error stays within the image-quality tolerance of the output. This paper presents a 16-bit selective approximate multiplier whose adder is partitioned at bit 8. In each of the lower eight-bit positions, an equality-controlled multiplexer selects either a newly generated sum or the preceding sum; the upper eight positions use an exact Brent–Kung prefix adder. The two middle-weight cross-terms of the product are omitted. The proposed multiplier and four reference architectures were implemented in Verilog, synthesized in Vivado 2026.1 for a Zynq-7020 field-programmable gate array and modelled in MATLAB for 3 × 3 Gaussian filtering of the Cameraman image. The proposed design uses 183 look-up tables and has a 2.959 ns critical path. It achieves a peak signal-to-noise ratio of 17.97 dB, compared with 7.69–8.13 dB for the reference designs, showing that the placement of approximation strongly affects the accumulated filtering error.
No takes yet. Share an insight, caveat, or question.
Sariki et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: