Answers are grounded in this paper and cite their sources.
Introduction: Amplicon-based next-generation sequencing (NGS) is widely used in clinical practice, yet few studies address the impact of fluorometric quality control and of low-volume or compromised paediatric samples on library quantification and sequencing metrics. We reframe this question around a practical goal: whether sub-optimal paediatric DNA can be reliably salvaged for custom-panel amplicon NGS. Materials and Methods: Data from 314 paediatric samples sequenced on 16 custom-designed amplicon panels (Ion Torrent S5) were analysed retrospectively by Qubit input quantity (Group A ≥ 10 ng/µL; Group B < 10 ng/µL) and Nanoquant A260/280 quality (Group C 1.7–1.9; Group D < 1.7 or >1.9), and compared against post-library quantification, mean depth, and ten coverage QC parameters. Method agreement (Bland–Altman, proportional-bias regression), effect sizes (Cliff’s δ), panel-adjusted mixed-effects models and ROC/logistic prediction of library failure were added. Results: Median input was 59.75 ng/µL by Nanoquant and 28.25 ng/µL by Qubit (p < 0.0001); median A260/280 was 1.86. Nanoquant overestimated DNA ~2.1-fold, but Bland–Altman analysis revealed wide, concentration-dependent limits of agreement (mean ratio 2.17×; 95% LoA 0.57–8.33×; proportional-bias p < 0.0001), indicating that no single correction factor is reliable. Group A comprised 91.7% (288/314) and Group B 8.3% (26/314); Group C 75.2% (236/314) and Group D 24.8% (78/314). Median post-library Qubit and mean depth were 1254 vs. 552 ng/mL (p < 0.0001) and 848× vs. 1352× (p = 0.025) for A vs. B, and 1254 vs. 1026 ng/mL (p = 0.049) and 745× vs. 1297× (p < 0.0001) for C vs. D. The higher depth in quantity Group B lost significance after adjusting for panel (mixed-model p = 0.083), identifying it as confounding. Input DNA predicted library failure (<300 ng/mL), with an ROC AUC of 0.79 and an exploratory empirical optimal threshold of ≈21 ng/µL (derived and tested in the same cohort; 14 failure events). None of the ten coverage QC parameters differed across groups. Discussion and Conclusions: Qubit quality control is strongly recommended because Nanoquant inflates readings ~2.1-fold, with no dependable correction factor. Low-volume or compromised paediatric DNA (<10 ng/µL and/or A260/280 outside 1.7–1.9) can be salvaged for amplicon NGS with defined protocol adaptations, with only ~19–23% of the worst-case samples failing library QC and comparable coverage in a small, concentration-matched representative subset (n = 5 per group) that was underpowered for formal equivalence testing. An empirical input threshold of ≈20 ng/µL, roughly double the manufacturer’s minimum, best protects against library failure.
No takes yet. Share an insight, caveat, or question.
Bhatia et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: