Answers are grounded in this paper and cite their sources.
The objective was to evaluate the accuracy of an ELISA for pregnancy specific protein B (PSP-B) for early pregnancy diagnosis in dairy cattle. Blood from lactating (>100 d postpartum) dairy cows (n = 738), was collected on Days 28, 30, and 35 (Day 0 = estrus), analyzed with an ELISA for PSP-B, and the cows designated as pregnant, probable, unlikely, or non-pregnant. Immediately after blood collection, transrectal ultrasonography (TRUS) was done for pregnancy diagnosis, and the results used as a criterion standard test for comparison with PSP-B. At Day 28, 46.3% were diagnosed by TRUS as pregnant. The PSP-B sensitivity was 93.9% on Day 28 and similar on Days 30 and 35. The PSP-B specificity, positive predictive value, negative predictive value, and accuracy were all >94% on Day 28 and similar on Days 30 and 35. However, the accuracy was significantly less compared to TRUS (P < 0.01). The percentage of all samples from cows that were probably pregnant or unlikely to be pregnant was 5.6%. At Days 28, 30, and 35, percentages of uncertain samples were 8.5, 4.8, and 3.3%, respectively (P < 0.01), and Kappa values were 0.92, 0.92, and 0.95. False negative and false positive results were attributed to low concentrations of PSP-B in pregnant animals and to persistence of pregnant concentrations of PSP-B in females with pregnancy loss, respectively. In conclusion, PSP-B ELISA was a sensitive, specific, and accurate test for pregnancy diagnosis (relative to TRUS) at Days 28, 30, and 35 after breeding.
No takes yet. Share an insight, caveat, or question.
Romano et al. (2010) studied this question.