Answers are grounded in this paper and cite their sources.
Amorphous-carbon thin films used as protective coatings for magnetic hard disks were subjected to wear by full-sized alumina-titanium carbide sliders. The associated microstructural changes were analyzed by Raman spectroscopy and high-resolution transmission electron microscopy (TEM). Raman spectroscopy did not detect structural differences between worn and unworn regions. However, TEM micrographs directly showed structural differences between worn and unworn regions, and indicated increased graphitic content. For comparison, unworn carbon samples were annealed and analyzed. The annealed unworn carbon films showed structural changes similar to those of worn samples. This paper presents the experiments and the correlation between the temperature and microstructure of the films, and proposes a wear mechanism.
No takes yet. Share an insight, caveat, or question.
Ramirez et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: