Key result
BioSTAR bioresorbable ASD occluders achieve complete host-tissue replacement by 2 years versus conventional devices.
Why the study?
An ideal septal occluder should promote complete healing and full resorption to minimize chronic foreign body complications and allow future transseptal left atrial access. This study tested whether interventional atrial septal defect closure can be performed safely and effectively using a bioresorbable occluder matrix.
Does transcatheter ASD closure using a bioresorbable collagen matrix occluder (BioSTAR) improve healing response and achieve full matrix replacement by host tissue compared to a conventional polyester occluder (STARFlex) in young sheep?
Does transcatheter ASD closure using a bioresorbable collagen matrix occluder (BioSTAR) improve healing response and achieve full matrix replacement by host tissue compared to a conventional polyester occluder (STARFlex) in young sheep?
In a preclinical ovine model, the BioSTAR septal occluder demonstrated complete bioresorption of its collagen matrix and replacement by host tissue over 2 years, supporting its evaluation in human clinical trials.
Bioresorbable ASD occluders merit first-in-human trials; leaves open whether they reduce chronic complications versus permanent devices.
Objectives We sought to test the hypothesis that interventional atrial septal defect (ASD) closure can be performed safely and effectively using a bioresorbable occluder matrix. Background The ideal septal occluder scaffold should promote the healthiest and most complete healing response while eventually facilitating the full resorption of the material and leaving "native" tissue behind, thus minimizing the potential for future complications from chronic foreign body and maintaining the possibility for later unobstructed transseptal access to the left atrium. Methods The STARFlex occluders (NMT Medical Inc., Boston, Massachusetts) were modified by substituting the conventional polyester fabric for a bioengineered, acellular type-I collagen matrix derived from porcine submucosa with a heparin-coated surface (BioSTAR occluder, NMT Medical Inc.). Comparative transcatheter closure of ASDs was performed in young sheep (n = 36). Gross pathology and histopathology were obtained after follow-up periods ranging from 7 days to 2 years. Results The STARFlex (control) devices were encapsulated time-dependently by ingrown fibrous tissue. Histology showed a mild but chronically persisting foreign body reaction. By contrast, BioSTAR devices exhibited a mild-to-moderate transient cellular immune response. Heparin coating of the BioSTAR surface improved the biocompatibility of the device by reducing surface thrombogencity. A remodeling process of the collagen scaffold, starting after 30 days in vivo, resulted in the full replacement of the matrix by host tissue after 2 years of follow-up. Conclusions The BioSTAR device is the first septal occluder with a totally bioresorbable matrix that is fully replaced by host tissue during the healing process. The promising results of this study support testing of the BioSTAR device in clinical trials.
No takes yet. Share an insight, caveat, or question.
Jux et al. (2006) studied Atrial septal defect (n=36). BioSTAR bioresorbable collagen matrix occluder vs. STARFlex polyester fabric occluder was evaluated on Gross pathology, histopathology, and matrix remodeling/resorption. BioSTAR bioresorbable ASD occluders started collagen remodeling after 30 days and achieved full matrix replacement by host tissue at 2 years in 36 sheep, unlike encapsulated STARFlex controls.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: