Key result
Isolated PR prolongation post-TAVI is linked to ~2.2-fold higher 1-year pacemaker risk.
Why the study?
Conduction system disorders are frequent complications following TAVI that often necessitate permanent pacemaker implantation. This study evaluated the predictive value of isolated PR interval prolongation for permanent pacemaker implantation within one year after TAVI.
Does isolated PR interval prolongation predict permanent pacemaker implantation within one year in patients undergoing transcatheter aortic valve implantation?
Cohort (n=600)
No
Does isolated PR interval prolongation predict permanent pacemaker implantation within one year in patients undergoing transcatheter aortic valve implantation?
Isolated PR prolongation following TAVI independently predicts permanent pacemaker implantation within one year, particularly in patients with wide baseline QRS complexes, warranting intensified rhythm monitoring.
Answers are grounded in this paper and cite their sources.
Isolated PR prolongation may flag higher PPM risk after TAVI; hypothesis-generating and leaves open need for prospective validation before monitoring changes.
Background Conduction system disorders are frequent complications following transcatheter aortic valve implantation (TAVI), with persistent conduction abnormalities often necessitating permanent pacemaker (PPM) implantation. Aim To evaluate the predictive value of isolated PR interval prolongation for PPM implantation within one year after TAVI. Methods We conducted a retrospective analysis of prospectively enrolled patients who underwent TAVI at our Hospital between September 2011 and March 2024. Patients with prior PPM, previous TAVI, patients in atrial fibrillation or missing ECG data were excluded. Baseline characteristics, procedural details, and serial ECGs were analyzed. The primary endpoint was PPM implantation within one year. Statistical analyses included logistic regression, Kaplan-Meier survival estimates, and Cox proportional hazards models. Results The cohort included 600 patients, divided into a study group (isolated PR prolongation, n=205) and a control group (no PR or QRS prolongation, n=395). At one year, PPM implantation occurred more frequently in the study group (13%) compared to controls (6.8%, p=0.01). Isolated PR prolongation was a predictor of PPM implantation (HR 2.22, 95% CI 1.25–3.93, p=0.006), particularly in patients with wide baseline QRS complexes, consistent after multivariable adjustment (aHR 1.01, CI 1.00–1.02, p= 0.013). Most patients reached maximum PR prolongation by day three post-TAVI. Conclusion Isolated PR prolongation after TAVI was an independent predictor of PPM implantation at one year, especially in patients with wide QRS complexes, highlighting the need for intensified monitoring in this subgroup.
No takes yet. Share an insight, caveat, or question.
Serban et al. (2026) conducted a cohort in Transcatheter aortic valve implantation (TAVI) (n=600). Isolated PR prolongation after TAVI vs. No PR or QRS prolongation was evaluated on Permanent pacemaker (PPM) implantation within one year (HR 2.22, 95% CI 1.25-3.93, p=0.006). Isolated PR prolongation after TAVI predicted 1-year permanent pacemaker implantation compared to no PR or QRS prolongation.
Synapse has enriched 10 related papers. Consider them for comparative context: