Key result
Pentaspline pulsed field ablation maintains similar 1-year effectiveness across BMI categories with low complication rates.
Why the study?
Obesity increases AF risk and recurrence while making ablation procedures more challenging, yet limited evidence is available on how body mass index influences patient safety and outcomes following pulsed field ablation.
Does body mass index influence safety and one-year clinical effectiveness (freedom from arrhythmia recurrence, repeat procedure, or cardioversion) in atrial fibrillation patients undergoing pentaspline pulsed field ablation?
Cohort (n=1,159)
Yes
Does body mass index influence safety and one-year clinical effectiveness (freedom from arrhythmia recurrence, repeat procedure, or cardioversion) in atrial fibrillation patients undergoing pentaspline pulsed field ablation?
Pentaspline pulsed field ablation demonstrates comparable safety and statistically non-significant differences in 1-year clinical effectiveness across BMI categories, supporting its use in patients with elevated BMI.
Similar safety across BMI groups with nonsignificant effectiveness trend; leaves open BMI impact on pulsed field ablation durability.
Introduction Pulsed field ablation (PFA) has become a preferential atrial fibrillation (AF) treatment modality, and as its use has expanded, patients with more complex comorbidities have undergone ablation. Obesity is associated with an increased risk of AF, challenging ablation procedures, and an increase in AF recurrence. However, limited evidence is available as to how body mass index (BMI) influences patient safety and outcomes following PFA. The FARADISE registry provides insights into real-world data after PFA. Purpose To assess safety and long-term outcomes of AF patients in relation to BMI. Methods The FARADISE registry is a prospective, real-world registry enrolling AF patients clinically indicated for a pentaspline PFA procedure across sites in Europe, Middle East, and Asia Pacific. All patients were treated per hospital standard-of-care. Patients were categorized by BMI (<25, ≥25 and <30, ≥30 and <35, ≥35 kg/m2), and procedural characteristics, safety, and one-year clinical effectiveness were assessed across BMI cohorts. Clinical effectiveness was defined as freedom from arrhythmia recurrence, repeat procedure, or cardioversion. Results The FARADISE registry treated 1159 patients, including 358 with a BMI <25, 478 with a BMI ≥25 and <30, 237 with a BMI ≥30 and <35, and 86 with a BMI ≥35. CHA2DS2-VA scores were consistent across patient BMI cohorts, while patient age inversely correlated with BMI (Table 1). Female sex (<25: 35%, ≥25 and <30: 30%, ≥30 and <35: 31%, ≥35: 49%, p<0.01) and diabetes history (<25: 8%, ≥25 and <30: 9%, ≥30 and <35: 16%, ≥35: 27%, p<0.01) increased with BMI, whereas paroxysmal AF indication decreased with BMI (<25: 72%, ≥25 and <30: 67%, ≥30 and <35: 57%, ≥35: 49%, p<0.01). Procedure times were similar across cohorts, although left atrial dwell time modestly increased with BMI (<25: 30 [24, 40] minutes, ≥25 and <30: 31 [23, 40] minutes, ≥30 and <35: 31 [25, 39] minutes, ≥35: 36 [27, 53] minutes, p<0.01). The pulmonary vein isolation (PVI)-only ablation strategy was not statistically different between BMI groups (<25: 75%, ≥25 and <30: 73%, ≥30 and <35: 72%, ≥35: 65%, p=0.36). Early-onset serious adverse events were low across BMI groups, ranging from 1.2% and 1.7% (p=0.98). Within the four BMI groups, clinical effectiveness decreased with increasing BMI, although the trend was not statistically significant (<25: 80%, ≥25 and <30: 76%, ≥30 and <35: 74%, ≥35: 69%, p=0.07) (Figure 1). Conclusion These findings highlight the applicability of the pentaspline PFA catheter among patients with elevated BMI, traditionally considered a high-risk and low-success population. This evidence supports the use of the pentaspline PFA catheter as an inclusive treatment strategy, with safe and effective procedures across a broad patient population.
No takes yet. Share an insight, caveat, or question.
Szegedi et al. (2026) conducted a cohort in Atrial fibrillation (n=1,159). Elevated body mass index (BMI ≥25 to ≥35 kg/m2) in patients undergoing pentaspline pulsed field ablation vs. Normal body mass index (BMI <25 kg/m2) was evaluated on One-year clinical effectiveness (freedom from arrhythmia recurrence, repeat procedure, or cardioversion) (p=0.07). Pentaspline pulsed field ablation showed non-significantly lower 1-year clinical effectiveness across increasing BMI groups (<25: 80% vs ≥35: 69%, p=0.07) with low serious adverse events (1.2%-1.7%).