Key result
Pulsed field ablation for atrial fibrillation in obese patients showed similar rates of major complications (1.2%-3.2%) and freedom from arrhythmia recurrence (67%-70%) compared to nonobese patients.
Why the study?
Catheter ablation outcomes for AF in patients with obesity have been mixed, and clinical data regarding pulsed field ablation in this cohort are limited.
Does pulsed field ablation prevent arrhythmia recurrence and maintain procedural safety in obese patients with atrial fibrillation compared to nonobese patients?
Observational (n=537)
No
Does pulsed field ablation prevent arrhythmia recurrence and maintain procedural safety in obese patients with atrial fibrillation compared to nonobese patients?
Pulsed field ablation using a pentaspline catheter demonstrates comparable procedural safety and clinical efficacy for atrial fibrillation across nonobese, obese, and morbidly obese patients, despite higher radiation exposure in the obese cohorts.
Supports consideration of pulsed field ablation in obese atrial fibrillation; leaves open randomized confirmation.
Background Procedural and clinical outcomes in patients with obesity undergoing catheter ablation for atrial fibrillation (AF) have been mixed. Clinical data in the context of pulsed field ablation (PFA) are currently limited in this patient cohort. Methods We conducted an observational study of consecutive patients undergoing PFA with a pentaspline catheter (Farapulse TM , Boston Scientific) for AF at a tertiary center comparing procedural and clinical outcomes in patients with body mass index (BMI) <30 kg/m 2 (nonobese), 30–34.9 kg/m 2 (obese), and ≥35 kg/m 2 (morbidly obese). Baseline and procedural characteristics, procedural outcomes (major and minor complications) and clinical outcomes were collected. Arrhythmia recurrence was defined as AF, atrial flutter or atrial tachycardia >30 s at any follow‐up. Results 537 (95%) out of 564 consecutive patients underwent de novo PFA for AF between 2022 and 2025 with a recorded BMI; 326 (60.7%) were nonobese, 117 (21.8%) were obese and 94 (17.5%) morbidly obese patients. Proportion of females increased according to BMI ( p = 0.003). Obesity correlated with CHA 2 DS 2 ‐VASc score, hypertension, diabetes mellitus, obstructive sleep apnea and heart failure with reduced ejection fraction ( p < 0.05 for all). Persistent AF was more common ( p = 0.048). Radiation exposure was significantly increased in obese patients ( p < 0.001). There was no difference in major (1.2%–3.2%) or minor (11%–15%) procedural complications between groups. There was no difference in freedom from arrhythmia recurrence between groups (67%–70% at median follow‐up 5.9–7.4 months). Conclusion Patients with obesity had no signal of increased risk detected with regard to procedural safety and clinical outcomes with PFA for AF compared with nonobese patients. These findings apply to a specific pentaspline PFA catheter rather than PFA technology in general.
No takes yet. Share an insight, caveat, or question.
Ha et al. (2026) conducted an observational in Atrial Fibrillation (n=537). Pulsed field ablation (PFA) with a pentaspline catheter vs. Nonobese patients (BMI <30 kg/m2) was evaluated on Procedural complications and freedom from arrhythmia recurrence. Pulsed field ablation for atrial fibrillation in obese patients showed similar rates of major complications (1.2%-3.2%) and freedom from arrhythmia recurrence (67%-70%) compared to nonobese patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: