Answers are grounded in this paper and cite their sources.
Endocrine disrupters are known to have negative effects on the environment and human health. Real time detection of vitellogenin, an endocrine disrupter biomarker, was demonstrated using AlGaN/GaN high electron mobility transistors (HEMTs). Anti-vitellogenin antibodies were chemically anchored to the gold-coated gate area of the HEMT and immobilized with thioglycolic acid. The potential difference that occurs from the vitellogenin antigen-antibody interaction-induced caused a drain current change in the HEMT. The HEMT sensor was tested for vitellogenin detection both in phosphate buffer saline and largemouth bass serum.
No takes yet. Share an insight, caveat, or question.
Chu et al. (2010) studied this question.