Key result
AI coronary motion analysis improves reduced EF prediction accuracy by ~30 percentage points.
Why the study?
Many patients with coronary artery disease present without traditional risk factors, creating a need for additional functional biomarkers. Although coronary artery motion on routine X-ray angiography reflects myocardial contraction and vascular mechanics, it remained underexplored as a quantitative biomarker due to challenges in robust, scalable extraction.
Does deep learning-extracted coronary artery motion from routine X-ray angiography accurately predict established cardiovascular risk factors and reduced ejection fraction compared to a no-motion baseline?
Observational (n=1,824)
Does deep learning-extracted coronary artery motion from routine X-ray angiography accurately predict established cardiovascular risk factors and reduced ejection fraction compared to a no-motion baseline?
Deep learning-extracted coronary artery motion from routine X-ray angiography significantly correlates with reduced ejection fraction and traditional cardiovascular risk factors, establishing its potential as a scalable functional imaging biomarker.
May enhance risk stratification from routine angiography; leaves open prospective validation before clinical adoption.
Background Cardiovascular disease remains a leading cause of mortality worldwide, and a considerable proportion of patients with coronary artery disease present without traditional risk factors, highlighting the need for additional functional biomarkers. Coronary artery motion observed in routine X-ray angiography reflects myocardial contraction and vascular mechanics but remains underexplored as a quantitative biomarker due to challenges in robust and scalable motion extraction. Purpose This study aimed to develop and validate a scalable deep learning framework to extract coronary artery motion from routine angiographic sequences and to evaluate associations between motion-derived representations and established cardiovascular risk factors. Methods In this retrospective study, >50,000 angiographic sequences from 1,824 patients were analysed. To reduce geometric variability, analyses were restricted to the dominant projection cluster, yielding 8,792 sequences. Nine consecutive peak-contrast frames per sequence were selected. Coronary motion between consecutive frames was quantified using a deep learning–based dense optical flow method and validated using synthetic transformations and reconstruction-based assessment on real data. Stacked motion fields were used to train a network capturing spatial and temporal coronary dynamics. Two video-based architectures were evaluated (a two-stream ResNet-152 and a transformer-based model), with the ResNet-152 demonstrating superior performance and selected for subsequent analyses. The network was trained to predict categorical clinical parameters. Results On synthetic data, motion estimation achieved a mean endpoint error of 0.50 pixels with 96.1% of displacements within one pixel. On real angiographic data, motion-based reconstruction reduced mean squared error from 1944.9 to 1710.6 and increased sensitivity from 0.49 to 0.55 compared with a no-motion baseline. Motion representations achieved higher accuracy for reduced ejection fraction (83.0% vs 53%, p<0.001), hypercholesterolaemia (68.4% vs 42%, p<0.001), hypertension (90.2% vs 68%, p<0.01), and nicotine use (81.5% vs 54%, p<0.001), with no significant improvement for diabetes. Conclusion Coronary artery motion can be extracted from routine X-ray angiography in a scalable, segmentation-free manner. Motion-derived representations demonstrate significant associations with established cardiovascular risk factors, supporting coronary motion as a promising functional imaging biomarker.
No takes yet. Share an insight, caveat, or question.
Moghbelan et al. (2026) conducted an observational in Cardiovascular disease / Coronary artery disease (n=1,824). Deep learning-based coronary artery motion representations (two-stream ResNet-152) vs. No-motion baseline was evaluated on Prediction accuracy for reduced ejection fraction (p=<0.001). Deep learning-derived coronary motion representations improved prediction accuracy for reduced ejection fraction (83.0% vs 53%, p<0.001) and hypertension (90.2% vs 68%, p<0.01).
Synapse has enriched 5 related papers. Consider them for comparative context: