Key result
Mitral annular area decreases ~11% during systole despite paradoxical lengthening in anterior segments.
Why the study?
Although prior reports attributed systolic mitral orifice reduction chiefly to posterior annular contraction with an unchanged anterior perimeter, segmental motion of the mitral anulus using true in vivo three-dimensional data had not been described.
Biplane videofluoroscopy demonstrates heterogeneous segmental shortening and lengthening of the mitral anulus during systole, indicating unexpected dynamic anterior flexibility.
The mitral anulus is a dynamic structure that undergoes alterations in size and shape throughout the cardiac cycle, contracting during systole. Numerous reports have shown this systolic orifice reduction to be due chiefly to posterior annular contraction, whereas the anterior perimeter was unchanged. Segmental motion of the mitral anulus from true in vivo three-dimensional data, however, has not been described. We used radiopaque markers and simultaneous biplane videofluoroscopy to measure the lengths of mitral anular segments in seven closed-chest, sedated dogs. Eight markers were placed equidistant from each other around the mitral anulus, As viewed from the left atrium, segment 1 began at the posteromedial commissure, and the remaining segments were numbered sequentially clockwise around the anulus (that is, the posterior mitral anulus encompassed segments 1 to 4 and the anterior anulus encompassed segments 5 to 8). Marker image coordinates obtained from two orthogonal views 7 to 12 days after implantation were merged to construct three-dimensional marker coordinates at end-diastole and end-systole. From end-diastole to end-systole, mean annular area decreased by 11% +/- 8% (5.5 +/- 0.9 cm2 to 4.9 +/- 0.8 cm2, p = 0.005) and perimeter by 5% +/- 4% (8.8 +/- 0.7 cm to 8.3 +/- 0.7 cm, p < 0.01). Mitral annular segmental percent systolic shortening (negative values indicate lengthening) were as follows (mean +/- standard deviation): segment 1, 7% +/- 9%; segment 2, 8% +/- 10%; segment 3, 16% +/- 6%; segment 4, 10% +/- 7%; segment 5, -4% +/- 5%, segment 6, -7% +/-7%; segment 7, 3% +/- 2%; and segment 8, 6% +/- 5%. With the exception of segment 1, all posterior (2 to 4) and two anterior (7 and 8) mitral annular segments contracted significantly (p < or = vs zero, paired t test). Two anterior annular segments (5 and 6, regions overlapping aortic-mitral continuity), however, unexpectedly lengthened during left ventricular systole. We conclude that the anterior mitral anulus may be a much more dynamic component of the mitral apparatus that previously thought. Such heterogeneous dynamic annular motion should be taken into account when various mitral valve reparative techniques are being designed.
No takes yet. Share an insight, caveat, or question.
Glasson et al. (1996) studied Normal mitral annulus dynamics (n=7). Radiopaque markers and simultaneous biplane videofluoroscopy was evaluated on Mitral annular area and segmental percent systolic shortening from end-diastole to end-systole (p=0.005). Three-dimensional biplane videofluoroscopy showed mitral annular area decreased by 11% (p=0.005) during systole, while anterior segments 5 and 6 lengthened (-4% and -7%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: