Key result
Higher right atrial voltage is linked to ~67% lower 12-month arrhythmia recurrence after AF ablation.
Why the study?
Although left atrial remodelling is known to contribute to the arrhythmogenic substrate in AF, the involvement of the right atrium and its impact on arrhythmia recurrence following left atrium-targeted catheter ablation remain incompletely understood.
Do right atrial structural, functional, and electrophysiological substrate perturbations independently predict arrhythmia recurrence within 12 months in patients undergoing first-time atrial fibrillation ablation?
Cohort (n=86)
Yes
Do right atrial structural, functional, and electrophysiological substrate perturbations independently predict arrhythmia recurrence within 12 months in patients undergoing first-time atrial fibrillation ablation?
Reduced right atrial bipolar voltage independently predicts arrhythmia recurrence within 12 months after first-time AF ablation, suggesting a role for right atrial substrate perturbations in post-ablation recurrence.
Answers are grounded in this paper and cite their sources.
May support right atrial voltage assessment for post-AF ablation recurrence risk; leaves open whether targeting right atrial substrate improves outcomes.
Background Although it is recognised that left atrial remodelling contributes to the arrhythmogenic substrate in atrial fibrillation (AF), the involvement of the right atrium remains incompletely understood. Right atrial substrate perturbations may contribute to arrhythmia recurrence following AF catheter ablation, which primarily targets the left atrium. Purpose To evaluate right and left atrial structural, functional, and electrophysiological predictors of AF recurrence following ablation and determine whether right atrial substrate perturbations independently predict recurrence risk. Methods In a multicentre, prospective, observational, cohort study, patients undergoing first-time AF ablation underwent pre-procedural cardiac magnetic resonance imaging (MRI) and intraprocedural bi-atrial electroanatomic mapping and electrophysiological assessment. Structural, functional, and electrophysiological parameters — including bi-atrial volume, ejection fraction, MRI-derived fibrosis burden, mean bipolar voltage, low voltage area, conduction velocity, wave collision percentage, and effective refractory period — were evaluated. Associations with arrhythmia recurrence were assessed using univariable Cox proportional hazards models for time to recurrence within 12 months excluding blanking period-only events. Significant predictors were examined in multivariable Cox models. Results Eighty-six patients were included, of whom 32 experienced arrhythmia recurrence. In univariable analysis, right atrial electroanatomic mapping parameters including mean bipolar voltage (HR 0.36, 95% CI 0.17–0.77, p=0.008), low voltage area percentage (HR 1.27, 95% CI 1.06–1.52, p=0.009) and wave collision percentage (HR 1.18, 95% CI 1.01–1.37, p=0.036) as well as left atrial low voltage area percentage were associated with recurrence (HR 1.15, 95% CI 1.03–1.28, p=0.016). In multivariable models adjusting each right atrial predictor for its corresponding left atrial parameter, mean right atrial voltage remained independently associated with recurrence (HR 0.33, 95% CI 0.12–0.90, p=0.031). Conclusions Reduced right atrial bipolar voltage is independently associated with arrhythmia recurrence following first-time AF ablation after adjustment for left atrial bipolar voltage. These findings suggest that perturbations in the right atrial substrate may contribute to arrhythmia recurrence following ablation. Further studies are warranted to define the role of right atrial substrate assessment in risk stratification and tailored ablation strategies.
No takes yet. Share an insight, caveat, or question.
Bodagh et al. (2026) conducted a cohort in Atrial fibrillation (n=86). Mean right atrial bipolar voltage (and right atrial substrate parameters) was evaluated on Time to arrhythmia recurrence within 12 months excluding blanking period-only events (HR 0.33, 95% CI 0.12-0.90, p=0.031). Mean right atrial bipolar voltage independently predicted 12-month arrhythmia recurrence after first-time AF ablation when adjusted for left atrial voltage.
Synapse has enriched 10 related papers. Consider them for comparative context: