Key result
Continuous finger blood pressure monitoring reduces sleep efficiency by ~5% and impairs sleep quality in healthy men.
Why the study?
The effects of continuous, non-invasive, beat-to-beat finger blood pressure monitoring on sleep in healthy men required investigation.
Answers are grounded in this paper and cite their sources.
Continuous finger BP monitoring modestly reduces sleep efficiency; leaves open effects on sleep in hypertensive or older patients.
OBJECTIVE: To investigate the effects of continuous, non-invasive, beat-to-beat finger blood pressure monitoring on sleep in healthy men. DESIGN: After 1 night of habituation to the laboratory environment, which consisted of the placement of electroencephalographic equipment without recording, polygraphic sleep recordings were performed during two consecutive nights (nights 1 and 2) in 15 healthy men (mean +/- SD age 25 +/- 6 years). Blood pressure was recorded continuously for 24 h from the end of night 1 to the end of night 2. RESULTS: The blood pressure recording procedure caused a decrease in the amount of rapid eye movement (REM) sleep and increased the duration of nocturnal awakenings. Consequently, sleep efficiency was decreased by approximately 5%. The blood pressure measurements did not affect the duration of light and of deep sleep. Although the respective predominance of deep sleep and of REM sleep at the beginning and at the end of the sleep period were preserved during the night of blood pressure recording, the blood pressure recording procedure hampered the rise in REM sleep during the final two thirds of the sleep period. CONCLUSION: In healthy young men continuous, non-invasive, beat-to-beat finger blood pressure monitoring induced modest reductions in sleep efficiency of similar magnitude to those observed previously with non-invasive ambulatory blood pressure monitoring.
No takes yet. Share an insight, caveat, or question.
Borne et al. (1993) studied Sleep quality during blood pressure monitoring in healthy men (n=15). Continuous, non-invasive, beat-to-beat finger blood pressure monitoring vs. Polygraphic sleep recording without blood pressure monitoring (night 1) was evaluated on Sleep efficiency, REM sleep duration, and nocturnal awakenings (Sleep efficiency decreased by ~5%). Continuous, non-invasive, beat-to-beat finger blood pressure monitoring decreased sleep efficiency by approximately 5%, reduced REM sleep, and increased nocturnal awakenings in healthy men.
Synapse has enriched 10 related papers. Consider them for comparative context: