Key result
Left bundle branch area pacing showed a non-significant trend toward higher peak VO₂ (18.5 vs 17.0 mL/kg/min; p=0.47) and workload (127 vs 99 W; p=0.73) compared with right ventricular pacing.
Why the study?
The impact of right ventricular pacing (RVP) on functional capacity in patients without pacing-induced cardiomyopathy remains poorly characterized, and no prior study had compared left bundle branch area pacing (LBBAP) with RVP during exercise.
Does left bundle branch area pacing (LBBAP) improve exercise capacity and cardiopulmonary response compared to right ventricular pacing (RVP) in patients without pacing-induced cardiomyopathy?
Cohort (n=14)
Non-randomized
Does left bundle branch area pacing (LBBAP) improve exercise capacity and cardiopulmonary response compared to right ventricular pacing (RVP) in patients without pacing-induced cardiomyopathy?
Answers are grounded in this paper and cite their sources.
In a small pilot cohort of patients without pacing-induced cardiomyopathy, left bundle branch area pacing showed a non-significant trend toward higher exercise workload and peak VO2 compared to right ventricular pacing.
Introduction Right ventricular pacing (RVP) can induce electrical and mechanical dyssynchrony, potentially impairing left ventricular performance and exercise tolerance, especially in patients who experience > 20% of RVP burden. Left bundle branch area pacing (LBBAP) provides a more physiologic alternative by engaging the native His–Purkinje system and preventing pacing induced cardiomyopathy (PICM). However, the impact of RVP on functional capacity among patients who do not develop PICM remains poorly characterized, and no study to date has compared LBBAP and RVP during exercise. Purpose To compare exercise capacity and cardiopulmonary response in patients who underwent LBBAP versus RVP implantation and who did not develop PICM, in a real-world cohort. Methods A prospective, non-randomized pilot study was conducted including patients undergoing CPET after LBBAP (n = 7) or RVP (n = 7) implantation. Baseline clinical, electrocardiographic, echocardiographic, and procedural characteristics were collected. CPET was performed on a cycle ergometer using a ram protocol. A short programmed atrioventricular interval (120 ms) ensured 100% pacing in each mode during exercise. Groups were compared using appropriate statistical tests. Results Baseline demographic, clinical, and echocardiographic characteristics were similar between groups. QRS duration was narrower in the LBBAP group (120ms vs 155ms) and all patients achieved maximal tests (RER > 1.10). Regarding functional capacity measures, although between-group differences did not reach statistical significance, LBBAP showed a consistent trend toward superior performance, including higher achieved workload (127 ± 38 W vs 99 ± 61 W; p = 0.73) and slightly higher VO₂ peak (18.5 ± 2.3 vs 17.0 ± 6.8 mL/kg/min; p = 0.47). Ventilatory efficiency (VE/VCO₂ slope), RER, and chronotropic response were comparable. Conclusions In this pilot cohort, LBBAP demonstrated a consistent trend toward improved exercise performance compared with RVP, despite the absence of statistical significance—likely influenced by limited sample size. These findings support the physiologic rationale of LBBAP and suggest that it may mitigate pacing-induced impairment during exercise, highlighting the importance of assessing functional capacity beyond resting left ventricular ejection fraction. Larger prospective studies are needed to validate these preliminary observations.
No takes yet. Share an insight, caveat, or question.
Araujo et al. (2026) conducted a cohort in Pacemaker implantation without pacing-induced cardiomyopathy (n=14). Left bundle branch area pacing (LBBAP) vs. Right ventricular pacing (RVP) was evaluated on Exercise capacity and cardiopulmonary response (VO₂ peak and achieved workload) (p=0.47). Left bundle branch area pacing showed a non-significant trend toward higher peak VO₂ (18.5 vs 17.0 mL/kg/min; p=0.47) and workload (127 vs 99 W; p=0.73) compared with right ventricular pacing.