Key result
Staged-release drug microneedle device improves vein graft lumen patency across all stages in mice.
Why the study?
Great saphenous vein graft patency after CABG critically determines prognosis, yet graft failure is driven by time-dependent processes of early thrombosis, intermediate intimal hyperplasia, and late atherosclerosis. A stage-specific drug-releasing protective device was developed to address this multi-stage pathological process of vein graft restenosis.
Does a hydrogel microneedle-based vein graft protection device releasing tirofiban, rapamycin, and rosuvastatin improve lumen patency in a mouse jugular vein transplantation model?
Does a hydrogel microneedle-based vein graft protection device releasing tirofiban, rapamycin, and rosuvastatin improve lumen patency in a mouse jugular vein transplantation model?
Answers are grounded in this paper and cite their sources.
A hydrogel microneedle device providing staged release of tirofiban, rapamycin, and rosuvastatin safely improves long-term vein graft patency in a preclinical mouse model.
Introduction Coronary artery bypass grafting (CABG) is a guideline-recommended treatment for severe coronary heart disease. The great saphenous vein is used as a bypass graft in approximately 80% of cases [2], and its patency critically determines patient prognosis. The primary mechanisms of graft failure are time-dependent: thrombosis predominates within the first week after CABG, followed by intimal hyperplasia from one month to one year, and subsequent atherosclerotic changes in the transplanted vessels after one year [3]. Purpose To address the pathological process of restenosis, we developed a hydrogel microneedle-based vein graft protection device capable of stage-specific drug release. Tirofiban is incorporated to prevent thrombosis, rapamycin to inhibit intimal hyperplasia, and rosuvastatin to suppress the progression of atherosclerosis. Methods Transmission electron microscopy (TEM) was used to observe the physical morphology of the device. Infrared spectroscopy was employed to evaluate drug incorporation into the device, and liquid chromatography-mass spectrometry (LC-MS) was used to assess in vitro drug release profiles. A mouse jugular vein transplantation model was established, including a control group, a drug-only control group, a blank device group, and a drug-loaded device group. Immunofluorescence staining was performed to observe drug distribution within the vascular endothelium at different stages. Ultrasound imaging was used to monitor the patency of transplanted veins. The CCK-8 assay was conducted to evaluate the safety of the drugs, and a hemolysis test was performed to assess the biocompatibility of the device. Results In vitro characterization of the device is shown in Figure 1.Panel A illustrates the preparation process.Panels B, C, and D show the naked-eye view, 60× magnified image, and TEM micrograph of the device, respectively. Panel E presents the infrared spectrum, confirming successful incorporation of all drugs.Panel F shows the in vitro drug release curve, indicating a staged release profile. Panel G depicts the mechanical properties of the device, demonstrating sufficient strength to penetrate the vascular adventitia. Panels H1, H2, and H3 display immunofluorescence images at 1 week, 1 month, and 1 year after surgery, respectively. At one week post-surgery, tirofiban was the predominant drug detected in the vascular endothelium; at one month, rapamycin was dominant; and at one year, rosuvastatin was primarily observed. Figure 2 summarizes the in vivo results. Panel A presents the lumen patency rates of each group at different time points,the device group improved the patency rate of the lumen at all stages. Panels B and C show the CCK-8 and hemolysis test results, respectively. Together, these findings demonstrate the effectiveness and safety of the device. Conclusions We have developed a safe and effective protective device targeting the pathological process of vein graft restenosis after CABG.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied Graft vein restenosis after CABG (preclinical mouse jugular vein transplantation model). Hydrogel microneedle-based vein graft protection device releasing tirofiban, rapamycin, and rosuvastatin vs. Control group, drug-only control group, and blank device group was evaluated on Lumen patency rate of transplanted veins. A hydrogel microneedle device releasing tirofiban at 1 week, rapamycin at 1 month, and rosuvastatin at 1 year improved lumen patency rates at all stages in mice.
Synapse has enriched 10 related papers. Consider them for comparative context: