The study examines the pre-investment selection of a small-scale mobile unit for associated petroleum gas (APG) utilization at a remote oilfield site. Three routes are compared: power generation for internal demand, generation linked to an external digital consumer, and synthetic-fuel production through a gas-to-liquids (GTL) process. Material and energy balances, capital and operating expenditures, net present value (NPV), and internal rate of return (IRR) are estimated for model configurations. The financial comparison is supplemented by multi-criteria assessment and decision gates preceding a final investment decision.Under the base assumptions, on-site power supply is the most resilient option. Its advantage results from a controlled load and a lower fixed-cost burden rather than from the highest theoretical product value. The proposed procedure links site data collection and front-end engineering design (FEED) with pilot operation, performance verification, and a replication decision. All numerical results are screening estimates and must be replaced by site-specific gas data, hourly load profiles, and vendor quotations before implementation.