Skin-like electrochemical sweat biosensors hold great promise for non-invasive and unobtrusive health monitoring, yet their real-world application is severely hindered by poor durability under repeated skin friction, stretching, and sweat erosion. Here, we report a versatile Janus bioelectrode design that simultaneously achieves ultralow thickness, high stretchability, and exceptional anti-friction performance for reliable sweat sensing. The Janus architecture prepared by sequential screen printing and thermal annealing, provides strong interfacial adhesion with strain-insensitive conductivity. The resulting ultrathin electrodes (∼20 µm) survive over 1600 s of Radio Corporation of America (RCA) abrasion and 500% tensile strain without significant degradation in conductivity or electrochemical stability. We further functionalized the Janus bioelectrodes into a durable three-electrode system for uric acid (UA) sensing. As a proof of concept, we attached the tattoo-like sensor onto a human forearm to enable real-time, wireless monitoring of sweat UA during both aerobic and anaerobic exercise. The sensor printed directly onto a T-shirt survived prolonged use and daily laundry cycles. This work establishes a general strategy for creating ultrathin, durable electrochemical biosensors that resist motion artifacts and friction, paving the way for robust and imperceptible electrochemical sweat analysis.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: