Vertical-axis wind turbines (VAWTs), including H-Darrieus rotors, are attractive for small-scale applications under variable wind conditions. Although airfoil-thickness effects have been examined for conventional NACA and other S-series profiles, systematic maximum-thickness variations of the symmetric S1046 airfoil remain insufficiently documented. This study therefore evaluates a three-bladed H-Darrieus turbine using the reference S1046 airfoil and six controlled maximum-thickness variations (−12.8%, −6.4%, +6.4%, +12.8%, +19.2%, and +32%). Transient two-dimensional URANS simulations, complemented by selected three-dimensional calculations, were performed in ANSYS Fluent 2020 R2 Fluent using the RNG k–ε turbulence model at a constant free-stream velocity of 6m/s and tested TSR values from 0.60 to 2.25. The corresponding local relative Reynolds number varied during rotor motion, with maximum values from 3.27×104 to 6.64×104 over the investigated TSR range. Among the tested configurations, the +19.2% thickness case produced the highest cycle-averaged power coefficient, CP¯=0.2692, comparable with 0.2589 for the reference S1046 airfoil, corresponding to an increase of 3.97%. The results indicate a non-monotonic thickness effect and identify +19.2% as the best-performing configuration among the discrete geometries investigated. The conclusions are restricted to the tested operating conditions and the adopted URANS numerical framework.
No takes yet. Share an insight, caveat, or question.
Martinez-Oropeza et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: