Watermarking chest radiographs requires limiting changes within lung fields while retaining payload recovery. We evaluated a map-assisted, host-image-independent transform-domain framework using three paired carrier-selection strategies: Global, reference-mask-guided GT-RONI, and U-Net-guided AI-RONI. A 112-bit message, rate-1/3 channel code, embedding strengths, and decoder were fixed on the Japanese Society of Radiological Technology (JSRT) dataset and transferred without retuning to 138 Montgomery radiographs. Relative to Global, AI-RONI reduced reference lung mean squared error by 51.9% internally and 45.7% externally. No-attack exact recovery was 20/20 internally (95% Wilson interval, 83.9–100.0%) and 84/138 externally (60.9%); GT-RONI achieved 60.1% externally. Controlled replacements characterized the balance between fidelity and recovery: the coefficient-pair alternative to singular value decomposition achieved 100.0% external no-attack recovery but zero recovery under the three tested processing operations, while omission of the discrete cosine Stockwell transform produced little change. Repeated Gaussian-noise and carrier-map-corruption tests further characterized decoder sensitivity. The framework provides a controlled basis for assessing anatomical exposure and payload transfer jointly across image sources.
No takes yet. Share an insight, caveat, or question.
Shafaie et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: