Answers are grounded in this paper and cite their sources.
Carbonation-induced corrosion of reinforced concrete threatens the durability of civil defense facilities, particularly where ventilation is insufficient and humidity is high. Purpose: The aim is to assess concrete carbonation and the risk of steel corrosion in reinforced concrete structures of civil defense facilities based on field inspections. Methodology: Field inspections are conducted in three shelters in Moscow built in the 1970s–1980s. The study included measurements of the CO₂ concentration, concrete carbonation depth using a phenolphthalein indicator, reinforcement potential, and diffusion-based carbonation modeling. Research findings: The carbonation front in the inspected facilities nearly reaches the reinforcement depth (20–26 mm), indicating the risk of corrosion initiation. The main factors identified are the insufficient ventilation (CO₂ concentration up to 0.3 vol.%), high (70–90 %) relative humidity, and concrete quality. Value: Without protective measures, some of structural elements may lose their load-bearing capacity within 5–10 years. It is recommended to include improving ventilation, applying waterproofing and protective materials, and implementing regular monitoring.
No takes yet. Share an insight, caveat, or question.
Burkovskaia et al. (2026) studied this question.