Two azo-containing materials, an acrylamide-derived azo compound (AZO 1) and a chitosan-derived azo material (AZO-chitosan 2), were prepared by diazo coupling with o-cresol under alkaline conditions at 0–5 °C. The acrylamide-derived monomer was subsequently converted to an azo polymer by free-radical photopolymerization under nitrogen using 1-hydroxycyclohexyl phenyl ketone (Irgacure 184) as the photoinitiator. The products were characterized by FTIR, ¹H NMR, and ¹³C NMR spectroscopy, and their thermal behavior was evaluated by TGA and DSC. The acrylamide-derived azo compound was obtained in 78% yield, whereas the AZO-chitosan product was obtained in 70% yield. The spectral changes support formation of the azo-containing products and consumption of the polymerizable double bond. The two polymer samples showed TGA onset temperatures of 110 and 100 °C, 50% mass-loss temperatures of 260 and 270 °C, and residues of 92% and 90% at 600 °C, respectively. DSC gave glass-transition temperatures of 180 and 250 °C. These results establish the structural and preliminary thermal characteristics of the prepared materials. Molecular-weight distribution and photoisomerization were not measured and therefore remain subjects for further study.
No takes yet. Share an insight, caveat, or question.
Abdulrada et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: