Answers are grounded in this paper and cite their sources.
Carbon monoxide (CO) concentrations within a tent may vary with height and duration of heater operation, complicating the interpretation of incident reconstructions. We measured CO and oxygen (O₂) at 0–10 cm and 140–150 cm above the floor during three full-scale trials with a liquefied-butane heater. Paired readings were analyzed at 3-min intervals from 3 to 39 min. Mean CO increased from 40.33 to 93.33 ppm at the upper position and from 8.67 to 101.67 ppm near the floor; descriptive linear slopes were 1.509 and 2.684 ppm/min, respectively. At 30 min, upper-minus-lower differences were − 2, −2 and + 4 ppm. All three differences were negative from 33 min onward. The 3–39 min time-weighted mean nevertheless remained higher at the upper position (62.99 versus 51.10 ppm). Mean O₂ declined from 20.03 to 16.80 vol% above and from 20.90 to 17.97 vol% below. Thus, the early upper CO excess was followed by higher near-floor readings in each trial, with variation in transition timing. These findings show why both measurement height and elapsed time matter when interpreting a tent reconstruction; they do not establish an individual inhaled dose.
No takes yet. Share an insight, caveat, or question.
Jihyuk Kim (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: