Answers are grounded in this paper and cite their sources.
Lung CT slice classification may support image-level decision assistance, but deterministic neural networks do not explicitly indicate when a prediction is unreliable. This study presents a lightweight uncertainty-aware convolutional neural network (CNN) for three-class classification of benign, malignant, and normal CT slices, integrating Monte Carlo (MC) Dropout, validation-selected selective referral, and Grad-CAM visualization. After removing 43 exact duplicate files, 1,054 IQ-OTH/NCCD images were analyzed using an image-level split of 842 training, 106 validation, and 106 test images (seed 42). Because reliable patient identifiers could not be recovered, the study is considered an internal image-level proof-of-concept rather than patient-independent diagnostic validation. With 50-pass MC Dropout, the model correctly classified 105/106 test slices, achieving 99.06% accuracy (exact 95% CI: 94.86–99.98%) and a weighted F1-score of 99.04%. The single misclassified benign slice was predicted as normal and exhibited high predictive uncertainty. Selective referral was based on the scalar uncertainty score U = max( 1 - Confidence,\,H_norm ,\,MI_norm ,\,VR ) , with a threshold selected as the 80th percentile of validation-set U values ( τU = 0.174166 ) , without using test labels or test performance. This operating point accepted 88/106 slices (83.02% coverage) and referred 18/106 (16.98%), with an observed accepted accuracy of 100% (95% CI: 95.89–100%) and an observed selective risk of 0% (95% CI: 0–4.11%). Calibration analysis yielded a 10-bin equal-width expected calibration error of 0.0295, a multiclass Brier score of 0.0137, and a negative log-likelihood of 0.0385. Deep Ensemble and Ensemble MC Dropout each correctly classified all 106 test slices, although these results remain subject to the same image-level data limitation. Simulated low-contrast and Gaussian-noise perturbations reduced accuracy and increased referral, indicating responsiveness of the uncertainty score to distributional degradation. A separately retrained binary lightweight CNN variant on the Chest CT-Scan Images Dataset correctly classified all 286 Cancer-versus-Normal test slices (100%; 95% CI: 98.72–100%), but its validation-selected referral rule accepted only 134/286 slices (46.85%) and referred all 25 Normal test slices. Therefore, the second-dataset experiment should be interpreted as a dataset-specific image-level benchmark rather than direct external validation of the primary three-class model. These findings support further patient-wise, multi-center evaluation of uncertainty-aware CT-slice classification and selective referral.
No takes yet. Share an insight, caveat, or question.
Khalid et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: