Key result
Dual-phase 100 kV prospective ECG-gated CTA is linked to ~48% lower radiation dose.
Why the study?
Conventional non-ECG-gated CTA for acute aortic dissection generates cardiac motion artefacts at the aortic root that compromise diagnostic accuracy while exposing patients to substantial radiation.
Does a dual-phase 100 kV aortic CTA protocol with prospective ECG-gating reduce radiation dose and improve aortic root image quality and diagnostic accuracy compared to conventional 120 kV non-ECG-gated CTA in patients with suspected aortic dissection?
Observational (n=80)
Single-blind
No
Does a dual-phase 100 kV aortic CTA protocol with prospective ECG-gating reduce radiation dose and improve aortic root image quality and diagnostic accuracy compared to conventional 120 kV non-ECG-gated CTA in patients with suspected aortic dissection?
A dual-phase 100 kV prospective ECG-gated CTA protocol cuts radiation exposure nearly in half and reduces scan time by 55% while virtually eliminating aortic root motion artefacts and achieving 100% diagnostic accuracy for Stanford Type A aortic dissection.
Answers are grounded in this paper and cite their sources.
May reduce radiation and improve Type A dissection diagnosis; hypothesis-generating and requires prospective validation before practice change.
Background and Objectives: Acute aortic dissection is a life-threatening condition. Computed tomography angiography (CTA) is the first-line modality; however, conventional non-ECG-gated protocols generate cardiac motion artefacts at the aortic root that compromise accuracy while exposing patients to substantial radiation. This retrospective study evaluated a dual-phase 100 kV aortic CTA protocol with prospective ECG-gating for dose reduction and improved image quality versus conventional 120 kV non-ECG-gated CTA. Materials and Methods: We retrospectively screened 80 consecutive patients with suspected aortic dissection undergoing CTA at Tianjin Chest Hospital (January 2024–December 2025) via the institutional Picture Archiving and Communication System (PACS) and electronic medical records. Patients were grouped by scanning protocol according to a historical control design: conventional 120 kV non-ECG-gated CTA (n = 40, January–June 2024) and dual-phase 100 kV CTA with prospective ECG-gating of the aortic root (n = 40, July 2024–December 2025). Image quality was assessed by subjective scoring and objective signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Effective dose, scan time, and diagnostic accuracy were compared between groups. Propensity score matching was applied to balance baseline characteristics. The ethics committee approved this study (no. 2024-LW-036; 15 December 2024) and waived informed consent. Results: The 100 kV protocol reduced effective dose by 48% (10.59 +/- 3.89 versus 20.25 +/- 3.28 mSv, p < 0.05) and scan time by 55% (11.36 +/- 1.41 versus 25.23 +/- 2.36 s, p < 0.05). The aortic root motion artefact rate fell from 90.0% to 7.5% (p < 0.05). SNR (24.35 +/- 2.25 versus 20.25 +/- 3.28) and CNR (44.10 +/- 2.47 versus 34.20 +/- 3.25) were significantly superior (both p < 0.05). Diagnostic accuracy for Stanford Type A dissection was 100% versus 80% (p < 0.05), with entry tear visualisation improving from 60.0% to 95.83%. Conclusions: The dual-phase 100 kV prospective ECG-gated protocol significantly reduces radiation exposure and scan duration whilst virtually eliminating aortic root motion artefacts and improving diagnostic accuracy for Stanford Type A dissection. These findings support adoption of this protocol as the preferred CTA technique for aortic dissection on 256-slice CT platforms.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) conducted an observational in Suspected aortic dissection (n=80). Dual-phase 100 kV CT angiography with prospective ECG-gating vs. Conventional single-phase 120 kV non-ECG-gated CT angiography was evaluated on Effective radiation dose (mSv) (p=<0.05). Dual-phase 100 kV prospective ECG-gated CTA reduced effective radiation dose by 48% (10.59 vs. 20.25 mSv, p<0.05) and improved Stanford Type A diagnostic accuracy to 100% vs. 80%.