Key result
DCB angioplasty reduces restenosis ~72% versus stenting in intracranial atherosclerotic stenosis.
Why the study?
Drug-coated balloon angioplasty and stent angioplasty have emerged as promising endovascular treatment options for intracranial atherosclerotic stenosis, but the comparative efficacy and safety of these two approaches remain uncertain.
Does drug-coated balloon angioplasty reduce restenosis and recurrent ischemic events compared to stent angioplasty in patients with intracranial atherosclerotic stenosis?
Meta-Analysis (n=723)
Does drug-coated balloon angioplasty reduce restenosis and recurrent ischemic events compared to stent angioplasty in patients with intracranial atherosclerotic stenosis?
Drug-coated balloon angioplasty significantly reduces restenosis and recurrent ischemic events compared to stent angioplasty in patients with intracranial atherosclerotic stenosis without increasing periprocedural complications.
Answers are grounded in this paper and cite their sources.
Supports preferring drug-coated balloons over stents for intracranial stenosis; extends evidence from randomized and cohort studies.
Background Intracranial Atherosclerotic Stenosis (ICAS) is one of the leading causes of ischemic stroke worldwide. Endovascular interventions such as drug-coated balloon (DCB) angioplasty and stent angioplasty (SA) have emerged as promising treatment options, particularly for patients with severe stenosis. However, the comparative efficacy and safety of these two approaches remain uncertain. This systematic review aimed to compare the efficacy and safety of DCB versus SA in patients with ICAS. Methods A comprehensive search of PubMed, Scopus, Web of Science, Embase, and the Cochrane Central was conducted through January 2026. We included randomized clinical trials and comparative cohort studies that compare DCB with SA in patients with ICAS. Results Six studies comprising 723 participants (332 DCB, 391 SA) met the inclusion criteria. The mean participant age ranged from 55.3 to 66.33 years. Compared with SA, DCB was associated with a lower overall restenosis rate (RR = 0.28, 95% CI: 0.18 to 0.44, p = 0.0007, I2 = 0.0%, τ2 = 0, PI = 0.16 to 0.48), and recurrent ischemic events (RR = 0.30, 95% CI: 0.22 to 0.42, p = 0.0002, I2 = 0.0%, τ2 = 0, PI = 0.13 to 0.72). No statistically significant difference in periprocedural complications was observed between the two strategies (RR = 0.78, 95% CI: 0.39 to 1.55, p = 0.3878, I2 = 0.0%, τ2 ≤0.0001, PI = 0.35 to 1.73). Conclusion DCB is associated with greater efficacy than SA in reducing restenosis and recurrent ischemic events in patients with ICAS without increasing procedural complications. However, interpretation of these findings is limited by the predominance of nonrandomized studies and relatively short follow-up durations. More randomized clinical trials with longer follow-up and larger sample sizes are needed.
No takes yet. Share an insight, caveat, or question.
Siam et al. (2026) conducted a meta-analysis in Intracranial Atherosclerotic Stenosis (ICAS) (n=723). Drug-coated balloon (DCB) angioplasty vs. Stent angioplasty (SA) was evaluated on Overall restenosis rate (RR 0.28, 95% CI 0.18-0.44, p=0.0007). Drug-coated balloon angioplasty reduced restenosis (RR 0.28; 95% CI 0.18-0.44) and recurrent ischemic events (RR 0.30; 95% CI 0.22-0.42) versus stent angioplasty in ICAS.