Answers are grounded in this paper and cite their sources.
As autonomous marine systems mature, they continue to address a wide range of societal needs, this growth extends into the ability to better understand water quality, especially in urban streams. Analyzing water quality is critical in these environments due to their proximity to people however operating in them can quickly become complex. A range of autonomous surface vehicles (ASVs) specifically designed for this task include the WasteShark produced by RanMarine Inc. This autonomous system has a proven track record collecting trash and debris however its efforts could be expanded to allow for collecting water quality measurements. This capability requires the ability to collect discrete water samples for analysis or a range of water quality conditions (particle number, size, harmful algal blooms, oxygen). This project is aimed at expanding the capabilities of the WasteShark by developing a tool to collect discrete samples using low-cost bottle collection systems. There are several challenges associated with water sample collection such that it can be an expensive, labor-intensive process that often requires specialized equipment. These challenges are exacerbated in remote, or harsh conditions. This study addresses these challenges by implementing a low cost, modular, remote water sample collection tool called “The Remora.” The Remora provides eight ~630mL Niskin Bottles that can be remotely activated to collect samples at any time during an ASVs mission. The Remora was tested on at a small pond on the Rutgers, New Jersey campus as part of its development, with plans for additional deployments in different water ways. The primary focus of this test was to verify the functionality of the bottles on a moving vessel (the WasteShark). This test was overall promising: bottles successfully closed every time it was prompted. However, there were some challenges in which the stoppers would “half close” on the bottles, allowing water to leak out, compromising the samples, and one bottle would not close at all. During two rounds of sample collection this issue occurred in the same three bottles, both times, giving us 12/16 successful samples collected. The cause of these limitations has been identified and corrected for, and in a laboratory setting there have been 16/16 bottle sealings observed. Preliminary analysis was done on the collections from this trial demonstrating variations in chlorophyll-a concentration between each of the bottles. This is likely related to the high spatial variability and highlights the importance of high frequency (high spatial and temporal resolution) sampling used to better understand the related processes in aquatic environments. Practically, these tests provide a foundation to continue development and take the WasteShark ASV with the Remora into various bodies of water and continue sample collection and analysis for these difficult to reach locations.
No takes yet. Share an insight, caveat, or question.
Elliot Christian Brown (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: