Answers are grounded in this paper and cite their sources.
The conductor temperature of a high-voltage direct-current (HVDC) cable limits its current-carrying capacity and governs the aging of the cross-linked polyethylene (XLPE) insulation. Transient finite-element (FE) simulation provides the full temperature field but is too expensive for online rating and digital-twin applications. This paper presents an autoregressive deep-learning surrogate for the three-dimensional cable temperature field. Exploiting axisymmetry, the network predicts the next field on a two-dimensional radial–axial grid from the previous H frames and the operating condition, and the three-dimensional field is reconstructed by revolution. ConvLSTM layers capture spatiotemporal correlations, a temporal Transformer fuses the history states, and a continuous condition embedding lets one model cover the operating space. A scaled residual-increment formulation and a rollout curriculum stabilize the 600 min closed-loop prediction. On a COMSOL dataset of 49 operating conditions (ambient temperature −20 to 40∘C, load current 0 to 1200 A), the surrogate achieves RMSEs of 0.28, 0.27, and 0.49∘C for training, interpolation, and extrapolation conditions, the latter being held-out corner combinations within the sweep ranges. It reduces the wall-clock time from about 110 s per FE simulation to 1.5 s per case (73× speed-up; 139× batched) and achieves lower mean RMSE than three baseline models.
No takes yet. Share an insight, caveat, or question.
Ruan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: