Key result
Incremental PEEP raises extracardiac pleural pressure, with transmural wedge pressure strongly correlating with LV area.
Why the study?
During positive end-expiratory pressure ventilation, elevated extracardiac pressure causes intracavitary filling pressure to not reflect ventricular preload. This study aimed to measure the cardiac constraining effect of the lungs and relate extracardiac pleural pressure to airway pressure, right atrial pressure, and left ventricular filling.
Does incremental positive end-expiratory pressure ventilation alter extracardiac pleural pressure and its relationship to airway pressure, right atrial pressure, and left ventricular filling in postoperative cardiac surgery patients with an open pericardium?
Observational (n=8)
Does incremental positive end-expiratory pressure ventilation alter extracardiac pleural pressure and its relationship to airway pressure, right atrial pressure, and left ventricular filling in postoperative cardiac surgery patients with an open pericardium?
In postoperative cardiac surgery patients with an open pericardium, pulmonary capillary wedge pressure minus extracardiac pleural pressure accurately predicts left ventricular end-diastolic area during positive end-expiratory pressure ventilation.
Answers are grounded in this paper and cite their sources.
Open-pericardium measurements during PEEP warrant caution for closed-chest application; leaves open translation to routine ventilation and hemodynamics.
Objectives This study was conducted to measure the cardiac constraining effect of the lungs during positive end-expiratory pressure and relate extracardiac pleural pressure (radial stress) to airway pressure, right atrial pressure and left ventricular filling. Background During positive end-expiratory pressure ventilation, the extracardiac pressure is elevated, and therefore intracavitary filling pressure does not reflect ventricular preload. Estimates of this pressure might be useful clinically to assess left ventricular preload. Methods In eight patients who had undergone coronary or valvular surgery and whose pericardium was left widely open, a flat pleural balloon transducer was placed over the anterolateral left ventricular wall. We recorded pulmonary capillary wedge pressure, right atrial pressure and left ventricular short-axis end-diastolic area by transesophageal echocardiography. Incremental positive end-expiratory pressure was applied. Results Extracardiac pleural pressure increased (p < 0.01) from 0.6 +/- 1.8 (+/- SD) to 2.4 +/- 1.8, 5.3 +/- 1.5 and 8.2 +/- 1.5 mm Hg at a positive end-expiratory pressure of 5, 10 and 15 cm H2O, respectively. The slope relating extracardiac pleural pressure to positive end-expiratory pressure (in mm Hg) was 0.70 +/- 0.10, and the intercept was zero. Increasing extracardiac pleural pressure was associated with a progressive increase in pulmonary capillary wedge pressure and a decrease in left ventricular end-diastolic area. Consequently, although pulmonary capillary wedge pressure and left ventricular area changed in opposite directions, the value of pulmonary capillary wedge pressure minus extracardiac pleural pressure correlated positively with left ventricular area (r = 0.95, p < 0.001). Changes in right atrial pressure (Pra) correlated with changes in extracardiac pleural pressure (Ppleural): delta Pra = -0.3 + 0.56. delta Ppleural (r = 0.89, p < 0.001). Conclusions In postoperative patients with open pericardium, pulmonary capillary wedge pressure minus extracardiac pleural pressure predicts left ventricular end-diastolic area during positive end-expiratory pressure. Further studies should be done to determine whether the observed relations between airway pressure and extracardiac pleural pressure and between right atrial pressure and extracardiac pleural pressure may give clinically useful estimates of left ventricular preload during positive end-expiratory pressure.
No takes yet. Share an insight, caveat, or question.
Smiseth et al. (1994) conducted an observational in Coronary or valvular surgery with open pericardium (n=8). Incremental positive end-expiratory pressure (PEEP) ventilation vs. Baseline (before PEEP increments) was evaluated on Correlation between pulmonary capillary wedge pressure minus extracardiac pleural pressure and left ventricular end-diastolic area (r = 0.95, p=<0.001). Incremental PEEP of 5, 10, and 15 cm H2O significantly increased extracardiac pleural pressure from 0.6 to 8.2 mm Hg (p<0.01), and PCWP minus pleural pressure correlated with LV area (r=0.95, p<0.001).