Key result
Forward and back aspiration in STEMI achieves optimal stent expansion without flow deterioration in ~100% of cases.
Why the study?
The inability to fully optimise stent expansion while simultaneously preventing distal embolisation during STEMI remains a clinical conundrum. This study evaluated a newly devised angiographic strategy of forward and back aspiration to achieve more complete thrombus removal and allow high-pressure stent post-dilatation.
Does a combined forward and back aspiration strategy allow safe high-pressure stent post-dilatation to the reference vessel diameter without distal embolisation in patients with STEMI?
Observational (n=30)
Does a combined forward and back aspiration strategy allow safe high-pressure stent post-dilatation to the reference vessel diameter without distal embolisation in patients with STEMI?
A novel combined forward and back aspiration technique using a guide catheter extension system appears feasible for enabling optimal high-pressure stent expansion during STEMI without compromising microvascular flow.
Answers are grounded in this paper and cite their sources.
May allow safe high-pressure post-dilatation in STEMI; leaves open confirmation in randomized trials.
AIMS: The inability to optimise stent expansion fully whilst simultaneously preventing distal embolisation during ST-elevation myocardial infarction (STEMI) remains a clinical conundrum. We aimed to describe a newly devised angiographic strategy of "forward" and "back" aspiration that leads to more complete thrombus removal and prevention of distal embolisation, to allow high-pressure post-dilatation of the implanted stent to be performed. METHODS AND RESULTS: Forward aspiration was conducted with a conventional aspiration thrombectomy catheter, with bail-out aspiration thrombectomy for angiographically persistent thrombus utilising the larger bore 6 Fr (0.056") guide catheter extension system (GuideLiner; Vascular Solutions, Inc., Minneapolis, MN, USA). Back aspiration was undertaken with a deeply intubated GuideLiner or guide catheter with a vacuum induced within, extending to the inflated angioplasty balloon, to allow for proximal embolic protection during balloon deflation during all stages of the PCI procedure, including high-pressure post-dilatation of the stent to the visually estimated reference vessel diameter (RVD). Over a six-month period 30 consecutive cases were undertaken during working hours. Bail-out GuideLiner-assisted aspiration thrombectomy was performed in 9/30 cases because of inadequate thrombus removal with a conventional aspiration thrombectomy catheter. Back aspiration was performed in all cases. In 27/30 cases high-pressure post-dilatation of the stent was performed. The mean maximum post-dilatation balloon size and mean proximal reference vessel diameter did not significantly differ (3.60±0.41 mm vs. 3.65±0.45 mm, p=0.68). In all cases, implantation +/- post-dilatation of the stent to the visually estimated RVD was achievable without any deterioration in TIMI blood flow or myocardial blush grade. CONCLUSIONS: The strategy of forward and back aspiration to facilitate stent implantation and high-pressure post-dilatation during STEMI appears to be safe and effective. Randomised controlled trials are required to confirm the safety and efficacy of this newly devised angiographic strategy.
No takes yet. Share an insight, caveat, or question.
Farooq et al. (2016) conducted an observational in ST-elevation myocardial infarction (STEMI) (n=30). Forward and back aspiration thrombectomy strategy using conventional catheter and 6 Fr GuideLiner was evaluated on Achievement of stent implantation +/- post-dilatation to the visually estimated reference vessel diameter without deterioration in TIMI blood flow or myocardial blush grade (p=0.68). Forward and back aspiration in STEMI allowed stenting/post-dilatation to reference vessel diameter in 100% (30/30) of cases without TIMI flow or myocardial blush deterioration.
Synapse has enriched 10 related papers. Consider them for comparative context: