Key result
Robot-assisted hybrid coronary revascularization shows no difference in 30-day MACCE versus conventional on-pump CABG.
Why the study?
This study aimed to compare the clinical outcomes of robot-assisted hybrid coronary revascularization (HCR) with conventional on-pump coronary artery bypass grafting (CABG) in patients with multivessel disease in the Netherlands.
Does robot-assisted hybrid coronary revascularization reduce major adverse cardiac and cerebrovascular events at 30 days compared to conventional on-pump coronary artery bypass grafting in patients with multivessel coronary artery disease?
Cohort (n=2,277)
Does robot-assisted hybrid coronary revascularization reduce major adverse cardiac and cerebrovascular events at 30 days compared to conventional on-pump coronary artery bypass grafting in patients with multivessel coronary artery disease?
Robot-assisted hybrid coronary revascularization provides short-term and midterm clinical outcomes comparable to conventional on-pump CABG while shortening hospital length of stay.
Answers are grounded in this paper and cite their sources.
Supports hybrid revascularization for shorter stays in selected multivessel patients; leaves open randomized validation of safety and durability.
Objective: Hybrid coronary revascularization (HCR) is minimally invasive coronary artery bypass surgery in patients with multivessel disease. This study compared the clinical outcomes of robot-assisted HCR patients with those receiving conventional on-pump coronary artery bypass grafting (CABG) in the Netherlands. Methods: We included 117 HCR and 2,160 CABG patients between January 2015 and December 2021. We performed a 1:3 propensity score matching (PSM) analysis. The primary outcome was the incidence of major adverse cardiac and cerebrovascular events (MACCE) at ≤30 days of follow-up. Secondary outcomes included red blood cell transfusions, length of stay, and the individual components of MACCE, which were mortality, perioperative myocardial infarction, revascularization of the target vessel (TVR), kidney failure, and in-hospital ischemic cerebrovascular accidents. Mortality and TVR at midterm follow-up were also included. Results: After PSM, 115 HCR and 342 on-pump CABG patients were included. HCR patients underwent a mean ± standard deviation of 1 ± 0 distal anastomosis, whereas CABG patients had a mean of 3.6 ± 1.1 distal anastomoses. At ≤30 days of follow-up, no differences in MACCE (odds ratio [OR] = 1.27, 95% confidence interval [CI]: 0.48 to 2.88, P = 0.57) or in the individual secondary outcomes were found. HCR resulted in a shorter hospital stay (OR = 0.99, 95% CI: 0.99 to 1.0, P = 0.02). At a median of 35 months (interquartile range [IQR], 23 to 45) of follow-up in the HCR group and 34 months (IQR, 22 to 45) in the CABG group, all-cause mortality and TVR did not differ. Conclusions: HCR provides excellent short-term and midterm outcomes, comparable to conventional CABG, while also offering faster recovery.
No takes yet. Share an insight, caveat, or question.
Jong et al. (2026) conducted a cohort in Multivessel coronary artery disease (n=2,277). Robot-assisted hybrid coronary revascularization (HCR) vs. Conventional on-pump coronary artery bypass grafting (CABG) was evaluated on Major adverse cardiac and cerebrovascular events (MACCE) at ≤30 days of follow-up (OR 1.27, 95% CI 0.48-2.88, p=0.57). Robot-assisted hybrid coronary revascularization showed no difference in 30-day MACCE compared with conventional on-pump CABG (OR 1.27; 95% CI 0.48-2.88; P=0.57).
Synapse has enriched 10 related papers. Consider them for comparative context: