Answers are grounded in this paper and cite their sources.
Evaporator designs of passive heat pipes for combustion air preheating in local space heaters have not been compared directly. This study compares two complete evaporator designs of a gravity loop heat pipe in a gas fireplace insert: a flat evaporator with a glass-fibre wick and a copper finned-tube evaporator. Two test series at four settings (4.5–9.6 kW) were compared with a reference without the heat pipe. The heat pipe transferred 953–2040 W to the combustion air (point velocity upper estimate; 523–1202 W from the excess air ratio), preheating it to 50–85 °C. The EN 613 efficiency rose by 1.5–5.7 percentage points at the combustion chamber boundary but changed by only −1.1 to +1.2 for the whole insert, as the evaporator also absorbs firebox radiation and preheating heat largely circulates internally. The finned-tube evaporator started up faster (10–29 vs. 33–42 min), but its series differed by up to 25%. At the highest settings, the flat evaporator lowered the flue gas temperature by 14–15 K but raised the glass temperature by 46–59 K. Loop pressures up to 6.6 bar limited operation. The evaporator design thus mainly affected start-up and firebox and flue gas temperatures; whole-appliance efficiency gains require lower flue gas temperatures.
No takes yet. Share an insight, caveat, or question.
Nová et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: