Key result
Automated CMR post-processing closely matches manual LV measurements, outperforming Inline scanner analysis.
Why the study?
Automated LV quantification in CMR imaging may reduce manual post-processing burden, but it requires evaluation against manual reference measurements and comparison with Inline scanner-derived measurements before routine clinical use.
Does automated CMR post-processing provide accurate left ventricular quantification compared to manual reference measurements and Inline scanner-derived measurements in patients undergoing cardiac magnetic resonance imaging?
Observational (n=178)
No
Does automated CMR post-processing provide accurate left ventricular quantification compared to manual reference measurements and Inline scanner-derived measurements in patients undergoing cardiac magnetic resonance imaging?
Automated CMR post-processing via syngo.via agrees closely with manual expert contouring for LV quantification and substantially outperforms raw Inline scanner outputs, supporting its integration into clinical workflows with selective expert review.
Answers are grounded in this paper and cite their sources.
Supports automated CMR post-processing for LV quantification; leaves open prospective validation before clinical adoption.
BackgroundAutomated left ventricular (LV) quantification may reduce the manual post-processing burden of cardiac magnetic resonance (CMR) imaging but requires evaluation against manual reference meas urements before routine clinical use. PurposeTo evaluate automated CMR post-processing for LV quantification against manual reference meas urements and to compare its performance with Inline scanner-derived measurements. MethodsCMR examinations from 178 patients at a single tertiary referral center were retrospectively evalu ated.Ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and myocardial mass obtained with automated syngo.viapost-processing and Inline scanner analysis were compared with manual expert measurements using intraclass correlation coefficients (ICC), Bland-Altman analysis, root mean square error (RMSE) and mean absolute percentage error (MAPE). ResultsAutomated post-processing showed excellent agreement with manual measurements for all five para meters (ICC 0.957-1.000;MAPE 0.72-3.21%).Bland-Altman mean biases were small: -0.83 per centage points for EF, 0.74 mL for EDV, -1.43 mL for ESV, -1.45 mL for SV and -1.03 g for myocardial mass, although ESV showed wider limits of agreement.Inline measurements showed greater disagreement with the manual reference, including an EF bias of +4.22 percentage points and moderate ICCs for SV (0.733), EDV (0.673) and ESV (0.619), with consistently higher RMSE and MAPE. ConclusionsAutomated CMR post-processing agreed closely with manual reference measurements and showed lower measurement error than Inline scanner-derived measurements, supporting its use to aid routine LV quantification with expert review where segmentation is uncertain.Further multicenter evaluation across scanners and patient populations is warranted.
No takes yet. Share an insight, caveat, or question.
Alharbi et al. (2026) conducted an observational in Cardiovascular patients undergoing cardiac magnetic resonance imaging (n=178). Automated CMR post-processing (Siemens syngo.via) vs. Manual expert reference measurements and Inline scanner-derived measurements was evaluated on Agreement of left ventricular ejection fraction (LVEF) between automated post-processing and manual reference measurements (ICC 0.996; Mean bias -0.83%, 95% CI 0.988-0.998, p=<0.001). Automated CMR post-processing achieved excellent agreement with manual LV measurements (ICC 0.957-1.000; MAPE 0.72-3.21%), outperforming Inline scanner analysis.
Synapse has enriched 10 related papers. Consider them for comparative context: